Product Center

Product Center
undefined
undefined
+
  • undefined
  • undefined

Oxford film thickness gauge

产品编号 X-Strata920

This page provides specifications and FAQs for the Oxford X-Strata920 film thickness analyzer. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Main components

1-1 Oxford Instruments’ X-Strata920 offers a simple, cost-effective X-ray thickness measurement solution. The standard configuration includes:
50 W power tungsten-target microfocus X-ray tube, color camera with 30× CCD magnification, and computer-controlled Z-axis focusing.
Optional collimator specifications (see the details in each configuration package description), Oxford Instruments based on the Windows operating system.
SmartLink® FP Test Software, a streamlined version for statistical analysis and report generation.
1-2 Computer Control System / Color Inkjet Printer / Simplified Chinese Windows 7 Operating System (OEM Genuine Version)
1-3 Cobalt Filter Assembly – a spectral filter used to eliminate copper interference when measuring nickel and copper.
1-4 Multi-collimator assembly
The most distinctive feature of this system is that it allows users to configure more than one collimator, with a maximum of six collimators.
A straightener, to enable selection of the spot‑detection range for the sample under analysis and to enhance analytical sensitivity.
Two circular collimators: 12 mil (0.305 mm) and 6 mil (0.15 mm)
Two rectangular collimators: 2x2 mil (0.05x0.05 mm) and 2x10 mil (0.05x0.25 mm)
1-5 XY-axis programmable sample stage (920-P XY Programmable Base)
The XY-axis programmable control system enables automated, program-controlled handling of analytical samples. Users can operate it with a mouse.
Alternatively, a control lever allows for convenient manipulation of the sample stage, enabling precise positioning of the measurement point. Through a simple…
The instrument enables automated measurement of samples. The standard size of the sample stage is 22 inches (56 cm) in diameter.
x 24 inches (60 cm) (W), with a maximum allowable sample height of 1.30 inches (3.30 cm). Move
The operating range is 6 inches x 7 inches (15.24 cm) x (17.78 cm).
2-1 Types of Coatings Quoted in the Inquiry (Applications Quoted Applications)
To ensure that you receive the most suitable instrument configuration and to guarantee the highest analytical accuracy for your application, the…
The required standard sample kit is provided; the detailed list is as follows. The types of coating and thickness ranges you have specified are as follows:
If there are any omissions or errors, please notify our company immediately, and we will revise the application list in accordance with your confirmation.
Au-Ni-Cu Sn-Ni-Cu
2-2 Standard samples required for the aforementioned applications (FP-STD Standards for Above Applications)
Foil-type standard wafers: one each of 4" and 20" Au.
Foil-type standard sample: one piece each of Ni 80" and Ni 160".
Foil-type standard sheet (Foil): Sn200, one piece
Foil-type standard wafer (Foil): Cu 80" per piece
Infinite‑Thickness Standard Foil (Infinite): One piece each of Au, Ni, Cu, Sn, and Zn.

Keywords:

牛津膜厚仪

膜厚仪

Recommended Products

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 1.0 Environmental Compliance Tester DX-320L

This page provides information on the Despu RoHS 1.0 DX-320L RoHS environmental testing instrument, including its specifications. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS 1.0 Environmental Compliance Tester DX-320L

RoHS environmental testing instrument

This page provides specifications for the RoHS tester DX-320, along with FAQs and other relevant information. For a quote, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS environmental testing instrument

Fully imported RoHS-compliant fluorescence spectrometer DX-520L

This page provides specifications for the fully imported RoHS‑compliant DX‑520L fluorescence spectrometer, along with answers to frequently asked questions. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Fully imported RoHS-compliant fluorescence spectrometer DX-520L

Latest News

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >