Automatic Alloy Analysis X-ray Fluorescence Spectrometer
产品编号 DP6300
The DP6300 Automated Alloy Analyzer X‑ray Fluorescence Spectrometer is a newly developed, fully automated instrument that integrates compliance with the RoHS Directive, the Halogen Directive, and the Eight Major Heavy Metals Directive. It combines five key attributes—accuracy, speed, non‑destructiveness, intuitiveness, and environmental friendliness—and incorporates cutting‑edge ultra‑fast detector technology from the analytical instrumentation industry.
(SDD) can reduce test time to 1 second. Leveraging advanced German technology, it enables image‑linked control and multi‑point continuous testing. An newly developed electric sample chamber enhances operational convenience, while a completely redesigned automatic sample stage ensures accurate measurements.
Key Performance Advantages:
Results in 1 second
It employs industry-leading ultra-fast detector technology—(SDD) with a resolution as low as 125 eV.
Advantages: large detection area (up to 25 mm²), high information throughput per unit time, high count rate, excellent resolution, higher detection efficiency, improved signal-to-noise ratio, and lower detection limits.
Adopts industry-leading digital multi-channel technology.
Advantages: Effectively enhances output efficiency, achieves an ultra‑high count rate, and ensures a maximum effective acquisition count rate of up to 10 million counts per second.
It employs a high-power X-ray tube and an advanced collimation-filter system.
Advantage: Higher efficiency in motivation
Optical shutter system
Advantages: Sample changes can be performed without shutting down the high voltage, enhancing both testing efficiency and accuracy.
Precision positioning system
Ultra-high-definition industrial camera, providing clearer visualization of test points.
Multi-point testing
2D Fully Automatic Motorized Sample Stage—enables image‑linked control and multi‑point continuous testing.
Ultra‑small sample testing—minimum detectable size: 0.2 mm
Eight collimators and four filters can be switched rapidly, allowing you to select the optimal configuration for each sample.
The collimator can achieve a minimum spot size of 0.2 mm, enabling precise focusing and accurate detection for ultra‑small samples.
Human-centered design
Enhanced Safety: X-ray Interlock Safety System—Optical Shutter and Interlock Device in Mutual Coordination; Instrument Enclosure Linked to High-Voltage Enable Terminal
Faster: Multi-point testing—test wherever you point.
Appointment Warm-Up: The instrument can start testing at a scheduled time according to the set timing.
Scheduled Power-On Warm-Up Function: Customers can schedule the instrument’s power-on time, enabling pre‑heating as well as automatic diagnostics and calibration of the instrument’s status. Additionally, a scheduled power-off function is available.
You can set an audio and visual alert before shutdown.
After-sales service
1. Free ROHS training and instrument operation instruction for 2–3 business days.
2. The software offers lifetime free upgrades, the most effective technical support, and rapid telephone response—within 4 hours of receiving a user’s fault report. Under normal circumstances, our technicians will arrive on-site to perform repairs and resolve issues within 24–72 hours nationwide; arrangements for pandemic-related situations will be discussed separately.
3. Installation, commissioning, acceptance testing, training, and technical services are all provided free of charge on-site at the customer’s premises, with training delivered to operating personnel.
4. The instrument is covered by lifetime maintenance, with free annual inspections and routine maintenance provided on a scheduled basis.
Keywords:
全自动化X荧光光谱
自动合金分析X荧光光谱仪
Recommended Products
Latest News
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.