Despu Instrument Human Body Temperature Detection Gate
产品编号 DP-EW3000
Technical Specifications
Operating voltage: AC 220 V, 50/60 Hz
Power: ≤35W
Signal frequency: 6–9 kHz (adjustable)
Operating temperature: -10°C to 50°C
Storage temperature: -25°C to 75°C
Overall package weight: approximately 71 kg
Shipping weight: approximately 95 kg (wooden crate)
External dimensions: 2200 mm × 820 mm × 630 mm
Channel dimensions: 2000 mm × 700 mm × 560 mm
Product Advantages
1. The detection speed is extremely fast, completing the test in just 1–2 seconds.
2. Extremely high precision and sensitivity—capable of detecting every single instance across 100 tests, with no false negatives or false positives, and with adjustable sensitivity settings.
3. Door panel material: high-density board with a fire-resistant veneer, supported by aluminum alloy uprights; it resists deformation, is fire‑retardant and moisture‑proof, and is highly scratch‑resistant, matching the materials and appearance of international brands exactly.
4. Customizable communication interfaces are available, enabling connectivity with computers, cameras, turnstiles, and other devices.
5. Digital Pulse Technology: Equipped with a digital signal processing and filtering system, it offers excellent resistance to electromagnetic interference.
6. Multiple operating frequencies can be configured, ensuring that multiple devices working side by side do not interfere with one another.
7. Password Protection Feature: Only by entering the correct password can system parameters be modified. The password can be set by the user, and in case of a forgotten password, a master password can be used to unlock the system.
8. Low‑field emission technology: Compliant with all currently applicable international safety standards, this low‑field technology poses no harm to pacemaker users, pregnant women, floppy disks, photographic film, videotapes, and similar items.
9. It adopts a modular design, making installation convenient and troubleshooting straightforward.
Comprehensive feature upgrade
1. Integrating infrared temperature measurement with metal detection, the system performs infrared body temperature screening at the security checkpoint, triggers voice alerts for abnormal temperatures, and effectively helps prevent the spread of large-scale infectious diseases.
2. The system has been comprehensively upgraded, with a highly integrated motherboard that requires no internal debugging; all functions are operated via the remote control.
3. Higher sensitivity, with a particularly noticeable improvement in copper detection capability.
Security Reference Standard
1. Complies with the current national standard for walk‑through metal detectors, GB 15210‑94.
2. Electrical appliances shall comply with the EN 60950 safety standard and meet the GB 2423 requirements.
3. Radiation and electromagnetic interference immunity shall be assessed in accordance with EN 50081‑1 and shall comply with GB 6833.
4. Electrical insulation and dielectric strength comply with the GB 10408 standard.
Precautions
1. This product is intended for indoor use only and must not be used outdoors in open-air conditions. If outdoor use is absolutely necessary, please install rain‑proof and sun‑proof protective devices to ensure that the sensor is not exposed to high temperatures or humid environments.
2. Within 1.5 meters of the detector, there should be no large, strongly magnetic metal objects, such as electrical equipment, to avoid interfering with the normal operation of the security gate.
3. Install the equipment as far as possible from areas with numerous power cables and instruments to avoid frequency‑based interference.
4. Personnel being screened should avoid colliding with the security gate body while passing through, and should not move too quickly—approximately one person per second.
5. Do not clean the security gate directly with water or a wet cloth; if cleaning is necessary, use a soft cloth dampened with alcohol.
6. High voltage inside the unit—do not open the machine without professional authorization.
Contact Person: Liu Menghan
Contact information: 18688929727
Address: Building 8, Shangxiawei Entrepreneurship Industrial Park, Shangsan Road, Sha Jing Subdistrict, Bao’an District, Shenzhen
Contact number: 0755-66862188
National Service Hotline: 400-688-7699
Keywords:
人体温度检测门
人体温度检测设备
Recommended Products
Latest News
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.