产品编号 IDP-6300
Product Overview
IDP6300 is a device that integrates RoHS Directive, Halogen Directive, and the Eight Heavy Metals Directive An all-in-one, fully automated X-ray fluorescence spectrometer (XRF), it combines five key attributes: accuracy, speed, non‑destructiveness, intuitiveness, and environmental friendliness. Equipped with cutting‑edge silicon drift detector (SDD) technology—the industry’s state of the art—this instrument reduces analysis time to as little as one second, dramatically boosting testing efficiency.
This instrument leverages advanced German technology to enable image‑linked control and multi‑point continuous testing. An newly integrated electric sample chamber enhances ease of operation, while a redesigned automatic sample stage ensures precise measurements. The IDP6300 not only detects heavy metals such as lead, mercury, cadmium, chromium, antimony, selenium, and arsenic in compliance with the RoHS Directive, but also analyzes halogen‑free‑compliant hazardous elements like bromine and chlorine, as well as metallic coatings—making it an ideal solution for meeting the EU and North American RoHS environmental regulations.
Core Technical Parameters
| Parameter item | Specification Details |
|---|---|
| Test subject | Powder, solid, liquid |
| Elemental analysis range | Sodium (Na) – Uranium (U) |
| Up to a maximum of elements can be measured simultaneously. | 36 types |
| Content analysis range | 1 ppm to 99.99% |
| Job stability | The total fluorescence intensity is 0.1%. |
| Test time | 60 to 200 seconds (as low as 1 second in Ultra‑Fast mode) |
| Detector resolution | 127 eV ± 5 (as low as 125 eV) |
| Processor | Imported 64-bit DSP digital signal processing chip |
| Multichannel Analyzer | 2048 questions |
| X-ray tube | Power: 50 W; target materials available: Ag, Rh, W, Mo. |
| High-voltage power supply | Voltage range: 0–50 kV; stability: less than 0.05% per hour. |
| External dimensions | 720 mm × 520 mm × 360 mm (excluding legs) |
| Measurement of the chamber dimensions | 590mm × 400mm × 120mm |
| Instrument weight | 60Kg |
| Limit of detection |
Cd/Cr/Hg/Br ≤ 1 ppm; Pb/Sb/Se/Ba ≤ 2 ppm; Cl ≤ 5 ppm |
Technical Parameters of Coating Thickness Measurement
| Parameter item | Specification Details |
|---|---|
| Number of measurable coating layers | Up to 5 layers |
| Types of Coatings | Single-metal plating, alloy plating |
| Coating identification accuracy | The analytical detection limit can reach 2 ppm, and the thinnest measurable thickness is 0.005 μm. |
| Light metal thickness range | Ti, Cr, etc.: 0.01–50 μm |
| Medium metal thickness range | Ni, Cu, Zn, Pd, Ag, Sn, etc.: 0.01–30 μm |
| Heavy metal thickness range | Pt, Au, Pb, etc.: 0.005–15 μm |
Standard configuration
Instrument host unit : One SDD detector, one low-power X-ray tube, one high-voltage power supply, one 2048-channel digital pulse analyzer, one high-precision CCD, five filter sets, and six collimators (with automatic switching among eight modes).
Peripheral configuration of the instrument : One branded computer (with a 19-inch LCD monitor), one HP color inkjet printer, one silver calibration slide, one bag of plastic standard samples EC681K, and several sample cups and Mylar films.
After-sales service
1. Free ROHS training and instrument operation instruction for 2–3 business days.
2. The software offers lifetime free upgrades, the most effective technical support, and rapid telephone response—within 4 hours of receiving a user’s fault report. Under normal circumstances, we dispatch technicians to your location for on-site repair and troubleshooting within 24–72 hours nationwide; arrangements for pandemic-related situations will be discussed separately.
3. Installation, commissioning, acceptance testing, training, and technical services are all provided free of charge on-site at the customer’s premises, with training delivered to operating personnel.
4. The instrument is covered by lifetime maintenance, with free annual inspections and routine maintenance provided on a scheduled basis.
Keywords:
卤素检测仪器
无卤检测仪
Previous:
Recommended Products
Latest News
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.