Infrared spectroscopy can be used to investigate molecular structure and chemical bonding, and it also serves as a method for characterizing and identifying chemical species. Infrared spectra are highly characteristic, allowing for analytical identification by comparison with the spectra of standardized compounds. By leveraging the characteristic wavenumbers associated with specific chemical bonds, one can distinguish between different classes of compounds and perform quantitative analyses. It is also applicable to the identification and characterization of various types of polymeric materials, among other applications.
Shenzhen Depu Instrument Co., Ltd. is headquartered in the picturesque High-Tech Innovation Strategic Emerging Industry Zone of the Dapqianhai Financial Center in Shenzhen, with its production base located in Shanghai. The company maintains branch offices in Shenyang, Chengdu, Wuhan, Hangzhou, Xiamen, Kunming, Guangzhou, Dongguan, and other cities. It is a high-tech enterprise specializing in the R&D, manufacturing, and sales of spectroscopic (XRF), chromatographic, and mass spectrometric products. The company wholly owns Shenzhen Shengwangda Instrument Equipment Co., Ltd. and Shenzhen Dezewei Testing Technology Co., Ltd., and holds controlling interests in Hong Kong Songsheng Electronics Co., Ltd. and the Longgang Wanda Industrial Park in Shenzhen.
Our R&D team, comprising X-ray fluorescence technology experts and German technical specialists, has developed X-ray fluorescence analytical products that hold a leading international technological position, enabling the identification, detection, and compositional analysis of various elements, as well as thickness measurement of coatings. Our spectrometers, chromatographs, and mass spectrometers are widely used across industries including nonferrous metals, geology and mining, electronics, electrical appliances, hardware, PCBs, semiconductors, telecommunications, electroplating, jewelry, and watchmaking. In addition, we offer comprehensive EU‑compliant environmental testing solutions—halogen‑free laboratories, RoHS‑compliant laboratories, and EU REACH‑compliant laboratories.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.