Effective July 1, 2006, the use of lead, mercury, hexavalent chromium, cadmium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) is prohibited in electrical and electronic equipment. The maximum allowable concentration for cadmium is 100 ppm (0.01%), while that for the other five substances is 1,000 ppm (0.1%). All products exported by companies to the European Union must comply with these limits and be accompanied by appropriate certification documents. Products that fail to meet these requirements will be denied entry into the EU market. The following provides an overview… RoHS Directive An instrument for detecting six hazardous substances.

I. X-ray fluorescence spectrometer

1. Scope of Application: Screening tests for lead, mercury, cadmium, total chromium, and bromine in plastic parts, metal components, and electronic assemblies—i.e., the six‑item RoHS compliance assessment.

2. Technical Features: Rapid qualitative analysis of lead, mercury, cadmium, chromium, and bromine in samples. Homogeneous samples require no preparation and can be analyzed non‑destructively. Note: The values for Cr and Br represent the total elemental content; exceeding the regulatory limit does not necessarily indicate that hexavalent chromium, PBBs, or PBDEs are also超标.

II. Fourier Transform Infrared Spectrometer

1. Scope of Application: Screening and detection of high levels of polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in polymeric materials, corresponding to the six‑item RoHS testing.

2. Technical Features: Based on the characteristic infrared spectra of polybrominated biphenyls and PBDEs, some samples can be analyzed non-destructively.

III. Gas Chromatography–Mass Spectrometry (GC-MS)

1. Scope of application: Quantitative analysis of polybrominated biphenyls and PBDE flame retardants in plastic components and electronic parts.

2. Technical Features: GC‑MS is a widely used method for the qualitative and quantitative analysis of volatile and semi‑volatile organic compounds, extensively applied to the residue analysis of various organic toxicants. It can also be employed to detect the four phthalates specified in RoHS 2.0.

IV. High-Performance Liquid Chromatograph (HPLC)

1. Scope of application: Quantitative analysis of polybrominated biphenyls and PBDE flame retardants in plastic components and electronic parts.

2. Technical features: This method is suitable for analyzing non-volatile flame retardants such as decabromobiphenyl and decabromodiphenyl ether, addressing the limitations of GC‑MS. It can also be used to detect the four phthalates specified in RoHS 2.0.

V. Spectrophotometer

1. Scope of Application: Hexavalent Chromium Content Testing

2. Main instrument: UV–Vis spectrophotometer;

3. Technical Features: This instrument employs a method for detecting hexavalent chromium and is compatible with numerous domestic and international standards, such as EPA Method 3060A.

VI. Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES)

1. Scope of Application:

Testing for lead, mercury, cadmium, and total chromium content in plastic parts, metal components, and electronic components.

2. Technical highlights: Samples are subjected to microwave digestion, wet digestion, and dry ashing, enabling the simultaneous determination of lead, mercury, cadmium, and total chromium in a single run.

VII. Atomic Absorption Spectrometer (AAS)

1. Scope of application: Testing the lead and cadmium content in plastic parts, metal parts, and electronic components.

2. Technical Features: AAS is one of the most established instrumental analytical techniques for metal elements, offering strong selectivity for characteristic atomic absorption lines and high sensitivity for elements such as lead and cadmium.

VIII. Cold Vapor Atomic Absorption Spectrometer (CVAAS)

1. Scope of Application: Plastic parts, metal parts, electronic components

2. Main instrument: mercury analyzer;

3. Technical highlights: Cold‑atom atomic absorption spectrometry is a classic method for determining mercury content, offering advantages such as high selectivity, low detection limits, and excellent sensitivity.

The above is an introduction to the testing instruments for the six hazardous substances specified in the RoHS Directive. For more information, please continue browsing our website. If you would like to learn more about these instruments, please call us or contact us online.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >