An Introduction to Chromatographic Analysis!
发布时间: 2022-12-07 10:17
Chromatographic analysis is also known as compositional analysis. Today, we’ll provide an overview of chromatographic analysis—those interested are welcome to learn more!

The chromatographic analysis method used in gas‑logging falls under the umbrella of gas chromatography. It employs an inert gas as the mobile phase and utilizes either an adsorbent (gas–solid chromatography) or a thin layer of a high‑boiling organic liquid coated on the surface of an inert solid support (gas–liquid chromatography) as the stationary phase to separate gas samples. The stationary phase packed into a tubular container of specified length is referred to as a chromatographic column. As the mobile phase carries the gas sample through the column, the components undergo repeated adsorption (in gas–solid chromatography) or dissolution (in gas–liquid chromatography). Because each component in the sample has a different adsorption capacity and distribution coefficient, their migration behavior within the column varies. If the column is sufficiently long, the component with the weakest adsorption or solubility will be eluted first, while the remaining components are separated one by one. The degree of separation depends on numerous factors, including column length, temperature, type of stationary phase, and carrier‑gas flow rate.
I. Principles of Chromatographic Analysis
Its principle is based on detecting chemical substances according to their differing distributions (or other distinct behaviors, such as adsorption or permeation) in two phases. One phase serves as the stationary phase, which may be solid or liquid, while the other is the mobile phase, which can be either liquid or gas. The separated components travel with the mobile phase and undergo repeated partitioning between the two phases. Because different substances have varying distribution coefficients between the two phases, they move at different rates, ultimately achieving separation. When this separation technique is combined with detection methods specific to each component, the resulting analytical approach is known as chromatography.
II. A Brief History of Chromatographic Analysis
Chromatography was first introduced in 1903 by the Russian botanist M. Tswett. He poured an ether extract of plant pigments into a vertical glass tube packed with calcium carbonate as the adsorbent (the stationary phase), then allowed petroleum ether (the mobile phase) to flow freely through the column. As a result, distinct colored bands formed within the tube, corresponding to the separation of different pigments from the original solution; hence the name “chromatography.” Subsequently, this technique was gradually extended to the separation of colorless substances, yet the term “chromatography” remained in use. Chromatography is sometimes also referred to as color‑layering or layering chromatography.
III. Classification of Chromatographic Analysis
From different perspectives, the classification of chromatographic methods typically includes the following approaches:
① Based on the physical state of the mobile phase, chromatography can be classified into gas chromatography and liquid chromatography. Considering that the stationary phase also exists in two forms—solid adsorbents and solid supports coated with a liquid—it can be further subdivided into gas–solid chromatography, gas–liquid chromatography, liquid–solid chromatography, and liquid–liquid chromatography. Within this classification, paper chromatography, thin-layer chromatography, ion-exchange chromatography, and gel-permeation chromatography are all categorized as liquid chromatography.
② Based on the nature of the stationary phase, chromatography can be classified into column chromatography, paper chromatography, and thin-layer chromatography. Column chromatography is further divided into two types: one involves packing the stationary phase into a metal or glass tube to form a chromatographic column, known as packed-column chromatography; the other entails coating the stationary phase onto the inner wall of the tube while leaving the center hollow, a technique referred to as capillary chromatography.
③ According to the underlying separation principles, chromatographic techniques can be classified into adsorption chromatography, partition chromatography, ion-exchange chromatography, and size-exclusion chromatography. Adsorption chromatography employs an active adsorbent as the stationary phase, exploiting differences in the physical adsorption properties of the components on the adsorbent surface. Partition chromatography separates components based on their differing distribution coefficients between two phases. Ion-exchange chromatography uses an ion-exchange resin as the stationary phase, achieving separation by leveraging variations in the ion-exchange capacities of the analytes. Size-exclusion chromatography utilizes a molecular-sieve gel as the stationary phase, separating components according to their molecular sizes. This method is also known as gel permeation chromatography. In addition, other techniques include complexation chromatography, electrochromatography, and thermal chromatography.
IV. Characteristics of Chromatographic Analysis
Chromatography is characterized by high separation efficiency, excellent selectivity, high sensitivity, rapid analysis, and minimal sample consumption. Depending on the properties of the analytes and the analytical requirements, different chromatographic techniques can be selected, which has led to its widespread application in fields such as agriculture. The emergence of advanced technologies like high-performance liquid chromatography and ion chromatography, along with the integration of chromatography with other analytical methods—such as chromatography–mass spectrometry and chromatography–spectroscopy—has continually expanded its scope of applications. In addition to qualitative and quantitative analysis, chromatography can also be used to prepare high-purity organic reagents and to purify samples.
The above is an introduction to chromatographic analysis. If you would like to learn more, please continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.