[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Proficient methods for operating a thermal desorption instrument
分类: News Center
发布时间: 2020-12-25 16:28
Proficiently operate the fully automatic thermal desorption instrument; these skills must be mastered.
The thermal desorption unit is a next‑generation instrument developed on the basis of a successful automated headspace sampler platform, fully leveraging its advantages of high sensitivity, excellent reproducibility, and zero memory effect. It employs innovative technologies—simultaneous desorption in sample tubes with low‑temperature focusing, followed by thermal re‑desorption using a hot gas stream—to deliver superior performance. Its intelligent color touchscreen user interface allows for convenient direct method setup, editing, storage, and retrieval, enabling rapid analysis initiation. Additionally, an advanced dynamic graphical display clearly illustrates the operational status of each stage in the sample extraction process, providing users with an intuitive overview of the instrument’s operation.
Precautions for using a thermal desorption unit:
1. When personnel are performing autoclave operations for the first time, at least one operator who is already proficient in operating the thermal desorption instrument must be present.
2. Operators shall handle tools and parts with care, avoiding any rigid impacts that could generate sparks.
3. During pressure relief, the exhaust gas from the high-pressure reactor shall be routed via a rubber hose to the outdoors or into a fume hood.
4. Verify that the fully automatic thermal desorption and desorption valves are open, as well as the pressure gauge valve.
5. Clean the air flotation tank and fill it with clean water; flush the pipelines and inspect them and the valves for leaks.
Product features of the thermal desorption analyzer:
Thermal desorption injection
Intelligent Sample Vial Transport System
“Mobile Oven” features unique technology, with temperatures reaching up to 350.
Direct thermal desorption from the sample tube into the GC inlet.
During sample injection, there is no heated transfer line or valve switching, and no sample carryover.
That concludes today’s comprehensive overview of the skills you need to master when using a fully automatic thermal desorption analyzer in your work. We hope this information proves helpful as you begin to operate this instrument.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.