[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Methods for detecting heavy metals using a heavy metal detector!
发布时间: 2022-12-01 10:25
Heavy metals are substances that pose risks to both the environment and human health. The development of heavy-metal detectors enables people to determine whether heavy-metal levels exceed regulatory limits. Below is an introduction… Heavy metal detector Methods for detecting heavy metals—those interested can learn more!
1. Methods and standards for detecting the heavy metal arsenic using a heavy metal detector
The national standard borohydride reduction–colorimetric method is employed: after sample digestion, potassium iodide–thiourea is added and the mixture is heated to reduce pentavalent arsenic to trivalent arsenic. Under acidic conditions, KBH4 further reduces trivalent arsenic to arsine, which is introduced into the absorbing solution and exhibits a yellow color. The arsenic content is determined by instrumental analysis.
2. Methods and standards for detecting lead, a heavy metal, using a heavy-metal detector
The national standard dithizone colorimetric method is employed: after sample digestion, lead ions form a red complex with dithizone under mildly alkaline conditions; this complex is extracted into CHCl3 and then quantified by spectrophotometry.
3. Method for detecting the heavy metal chromium using a heavy metal detector
After sample digestion, in the presence of divalent manganese, chromium ions react with diphenylcarbazide to form a purplish-red complex. The color intensity of the complex is directly proportional to the hexavalent chromium content, which can be determined by spectrophotometric analysis.
4. Method for Detecting Cadmium, a Heavy Metal, Using a Heavy Metal Detector
The national standard colorimetric method is employed: after digestion, cadmium ions form a red complex with 6-bromo‑benzyl‑thiazolyl‑azo‑naphthol under alkaline conditions; this complex is soluble in CHCl3 and is quantified by colorimetry.
5. Method for Detecting Mercury, a Heavy Metal, Using a Heavy Metal Detector
The national standard dithizone colorimetric method is employed: after sample digestion, under acidic conditions, mercury ions form an orange‑red complex with dithizone, which is soluble in CHCl3; the concentration is then determined by spectrophotometry.
6. Method for detecting the heavy metal nickel using a heavy metal detector
The national standard dimethylglyoxime colorimetric method is employed: after sample digestion, a peroxide is added under strongly alkaline conditions, and nickel forms a reddish-brown complex with dimethylglyoxime. The intensity of the complex’s color is directly proportional to the nickel content, which can be determined by colorimetric analysis.
7. Method for Detecting Heavy Metal Iron Using a Heavy Metal Detector
After sample digestion, iron is reduced to ferrous iron by a reducing agent. Within a pH range of 2–9, ferrous iron reacts with o-phenanthroline to form an orange‑red complex. The color intensity of the complex is directly proportional to the iron concentration, allowing iron content to be determined by spectrophotometric analysis.
8. Method for detecting the heavy metal aluminum using a heavy metal detector
Using the national standard chromazurol S colorimetric method, after sample digestion, trivalent aluminum ions react in a buffer solution with chromazurol S and cetyltrimethylammonium bromide to form a blue ternary complex. The color intensity of the complex is directly proportional to the aluminum content, which can be determined by spectrophotometric analysis.
9. Method for Detecting the Heavy Metal Zinc Using a Heavy Metal Detector
Using the national standard dithizone colorimetric method, after sample digestion and under appropriate pH conditions, zinc ions form a purple complex with dithizone. The intensity of the complex’s color is directly proportional to the zinc concentration, which can be determined by colorimetric analysis.
10. Method for Detecting the Heavy Metal Manganese Using a Heavy Metal Analyzer
After sample digestion, the divalent manganese ions in the solution to be analyzed are oxidized to purplish‑red permanganate under acidic conditions by an oxidizing agent of appropriate strength, followed by colorimetric determination, which allows for the quantification of manganese content.
The above is an introduction to the methods used by heavy-metal detectors to detect heavy metals. If you would like to learn more, please continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.