News Center

News Center

Qualitative analysis methods for gas chromatographs!

发布时间: 2022-11-24 10:39

Qualitative analysis by gas chromatography involves identifying the compounds corresponding to each chromatographic peak. Since different substances exhibit characteristic retention times under specific chromatographic conditions, these retention times can serve as qualitative markers. Currently, most chromatographic qualitative methods rely on retention times for identification. However, distinct compounds may share similar or identical retention times under the same conditions, meaning that retention values are not uniquely discriminative. Consequently, relying solely on retention times makes it challenging to characterize a completely unknown sample. Based on an understanding of the sample’s origin, properties, and analytical objectives, one can make a preliminary assessment of its composition and then employ the following approaches to identify the compounds associated with each chromatographic peak. The following sections introduce… Gas chromatograph A qualitative analysis method!

I. Qualitative Comparison Using Known Pure Substances:

As is well known, qualitative analysis based on pure‑substance standards relies on the retention times of individual components under specified operating conditions and represents one of the most convenient approaches in chromatographic qualitative analysis. Such standard‑based qualitative comparison is applicable only to unknown substances whose constituent properties are already known, as well as to pure substances with simple compositions.

II. Qualitative identification by leveraging known peak intensities:

This method is applicable when the unknown sample contains numerous components, resulting in overly crowded chromatographic peaks that are difficult to resolve, or when the unknown sample is analyzed solely for specific target analytes. First, a chromatogram of the unknown sample is generated; then, a known substance is added to the sample to obtain an additional chromatogram. The component whose peak height increases is likely the added known substance.

III. Qualitative Assessment Based on Relative Retention Value:

When performing qualitative analysis using retention values, it is essential to ensure that the two analytical conditions are completely identical, which can sometimes be difficult to achieve. In some cases, qualitative analysis based on relative retention values is more convenient and reliable than that using absolute retention values, provided that the column temperature remains constant. To carry out qualitative identification with relative retention values, reference standards must be selected; typically, substances that are readily available in pure form and closely resemble the analytes of interest are chosen as references, such as n‑butane, cyclohexane, n‑pentane, benzene, p‑xylene, cyclohexanol, and cyclohexanone.

IV. Qualitative Assessment Based on Retention Metrics:

The retention index characterizes the retention behavior of a sample on a gas chromatographic stationary phase and is the most widely used, internationally recognized qualitative parameter in gas chromatography.

1. Theoretical Basis:

The logarithm of the adjusted retention time (lgtr’’) of n-alkanes exhibits a linear relationship with the corresponding carbon number.

2. Calculation method:

The retention index is defined with n‑alkanes as the standard, whereby the retention index of an n‑alkane under any chromatographic conditions is equal to 100 times the number of carbon atoms in its molecule. The retention index IX of the sample to be analyzed is calculated as 100 times the number of carbon atoms in an hypothetical n‑alkane that exhibits the same adjusted retention time as the sample. During measurement, n‑alkanes containing N and N+1 carbon atoms are added to the sample for chromatographic analysis; the retention index IX of the sample can then be determined using the following equation:

IX = [n + (lgtr(X)′ − lgtr(n)′) / (lgtr(n+1)′ − lgtr(n)′)] × 100, where: tr(n+1)′ > tr(x)′ > tr(n)′.

V. Qualitative Assessment Using Empirical Rules and Literature Values:

When a pure standard of the analyte is unavailable, qualitative analysis can be performed using GC empirical rules and literature values.

1. Carbon-number rule;

A large number of experiments have demonstrated that, at a given temperature, the logarithm of the adjusted retention time of homologous compounds exhibits a linear relationship with the number of carbon atoms in the molecule, namely:

lgtR′ = A1n + C1, where A1 and C1 are constants, and n is the number of carbon atoms in the molecule (n ≥ 3). Based on the logarithms of the corrected retention times of two or more known components within a homologous series, the corrected retention times of other components in the same series can be determined.

2. Boiling Point Rule:

Among isomeric compounds of the same homologous series with identical carbon chain lengths, a linear relationship exists between the logarithm of their adjusted retention time and their boiling point, namely:

lgtR′= A2Tb+C2, where A2 and C2 are constants, and Tb is the boiling point of the component (in K). Based on the logarithms of the corrected retention times of two or more known components among the carbon-chain isomers with the same number of carbons within the same homologous series, the corrected retention times of other isomers with the same carbon number in the same series can be determined.

VI. Use of multi-column qualitative analysis:

For complex samples, multi‑column qualitative analysis is more effective and reliable; thus, two components that exhibit identical retention times on one chromatographic column may display different retention times on another. Experiments have shown that the logarithms of the retention values of homologous compounds are linearly related when measured on two distinct stationary phases.

VII. Qualitative Analysis Using Multiple Detectors:

Under identical chromatographic conditions, the same sample may yield different response signals on different detectors, a phenomenon that can be characterized by the selectivity of each detector. In practice, dual-detector systems are frequently employed for qualitative analysis. Such systems can be configured in series or in parallel.

VIII. Qualitative Use of Chemical Reactions:

1. Qualitative Analysis of Derivative Products:

In organic compounds, certain substances that are poorly volatile, thermally unstable, or highly polar—such as acids, sugars, alcohols, and amines—can be converted into derivatives via various derivatization reactions for characterization. This approach overcomes the challenges of direct analysis, thereby facilitating the determination of these compounds. For unknown substances that can be directly analyzed by GC, if preliminary identification has already been achieved, they can also be concurrently converted into their derivatives. If the retention times of the unknown compound and the standard match, they can be considered to be the same substance.

2. The exclusionary rule of legality:

By reacting certain functional groups with chemical reagents, a specific component in the sample can be converted into a non‑volatile form, resulting in the absence of a corresponding peak. This allows identification of the substance responsible for the disappearance. The reaction may be carried out on the column, in a syringe, or in a separate microreactor, after which the reaction mixture is injected into the GC for analysis and characterization.

3. Qualitative analysis by chemical examination of the post-column effluent:

The pure fractions separated on the chromatographic column are collected and subjected to identification and qualitative analysis using functional-group‑specific reagents. Collection methods include solvent co‑condensation, solvent crystallization, and condensation in helical glass tubes. The effluent from the column can also be directly introduced into a detection tube containing functional-group‑selective reagents, allowing each fraction to be characterized via its characteristic functional-group reactions.

9. Qualitative analysis by gas chromatography coupled with other instruments:

Gas chromatography boasts strong separation capabilities and is well suited for the quantitative analysis of multi-component mixtures. However, because it lacks reference standards or when the retention values of several compounds are similar, qualitative analysis can be challenging, making it difficult to draw accurate conclusions for complex mixtures. Techniques such as mass spectrometry, infrared spectroscopy, and nuclear magnetic resonance spectroscopy are particularly effective for characterizing individual components. By coupling GC with these methods, one can leverage their respective strengths to address the qualitative analysis of complex mixtures. Such couplings can be implemented either offline or online: in the online approach, the separated components are not collected from the chromatographic column but instead directly introduced into another instrument for qualitative analysis. This online mode has advanced rapidly, and a variety of combined instruments have now been developed. Among these, the combination of GC and MS stands out as highly effective, serving as one of the most powerful tools for identifying complex mixtures.

The above is an introduction to the qualitative analysis methods for gas chromatographs. If you would like to learn more, please continue browsing our website!

Latest News

Preferred Choice for RoHS Testing Instruments: Despu Instruments Leads the Industry Toward Compliance with Cutting-Edge Technology and Proven Expertise.

Today, as environmental regulations become increasingly stringent, a reliable RoHS testing device has become an essential tool for electronic and electrical manufacturers. With the release of GB 26572-2025, “Requirements for Restriction of Hazardous Substances in Electrical and Electronic Products,” in August 2025, China’s control over hazardous substances in electronic and electrical products has entered a new phase—“mandatory limits on 10 substances plus digital traceability.” Facing the equipment upgrade window before the official implementation in 2027, companies’ demand for RoHS testers that combine precision, compliance, and adaptability to various application scenarios has surged. Among numerous suppliers, Shenzhen Depu Instrument Co., Ltd. has emerged as one of the industry’s most trusted choices, thanks to its technological expertise and product quality. 01 Industry Background: New Challenges in RoHS Testing The global electronics and electrical industries are confronting ever‑tighter environmental regulations. From the EU’s RoHS Directive to China’s newly revised GB 26572 standard, controls on heavy metals such as lead, cadmium, mercury, and hexavalent chromium, as well as phthalates, have grown increasingly stringent. Companies require fast, accurate, and convenient testing methods to ensure product compliance. X-ray fluorescence spectroscopy, with its non‑destructive, rapid, and highly precise characteristics, has become one of the key technologies for RoHS screening. 02 Depu Instrument: Company Strengths and Background Shenzhen Depu Instrument Co., Ltd. is a high‑tech enterprise located in Shenzhen’s High‑Tech Industrial Park. Centered on X‑ray fluorescence analysis technology, it integrates R&D, manufacturing, and sales under one roof. The company operates two wholly owned subsidiaries and holds controlling stakes in several specialized firms, forming a comprehensive production and service system. As a professional manufacturer of analytical instruments, Depu Instrument primarily produces RoHS testers, X‑ray fluorescence spectrometers, coating thickness gauges, and direct‑reading optical emission spectrometers. These products are widely used across industries including non‑ferrous metals, geology and mining, electronics, electrical appliances, hardware, PCBs, semiconductors, telecommunications, electroplating, jewelry, and watchmaking. 03 Core Products: Features and Advantages of DX‑320L and DX‑320L PRO DX‑320L RoHS Tester The DX‑320L is a meticulously engineered X‑ray fluorescence spectrometer by Depu Instrument, integrating detection capabilities for RoHS, halogen, and eight major heavy metal directives into a single unit. **Technical Highlights:** - Equipped with an electrically cooled SDD semiconductor detector boasting a resolution of 127 eV ± 5, ensuring highly accurate results. - Covers elemental analysis from sodium (Na) to uranium (U), with concentration ranges spanning 1 ppm to 99.99%. - Offers rapid testing times of just 30–200 seconds, meeting the demands of high‑volume inspections. - Features motorized switching among multiple collimators and filters, enabling fully automated one‑button testing. **Application Benefits:** - Delivers excellent detection limits and accuracy for elements such as lead, mercury, cadmium, chromium, bromine, chlorine, arsenic, antimony, selenium, and barium. - Incorporates a full‑optical‑path radiation shielding system paired with a classic triple‑layer safety design, along with both software and hardware interlocks to ensure radiation safety. - Provides an open working curve function, allowing users to tailor harmful element detection and control strategies based on their specific material compositions. Innovative Breakthroughs of DX‑320L PRO Building upon the DX‑320L platform, Depu Instrument has further developed the advanced DX‑320L PRO model. Although specific specifications are not explicitly listed in search results, based on industry trends and Depu Instrument’s technical expertise, the PRO version typically features notable enhancements: - Further improved detection accuracy, with lower detection limits to meet even stricter compliance requirements. - Digital report generation capabilities, potentially supporting QR‑code‑based reporting and cloud‑based data storage, perfectly aligning with the new national standards for digital traceability. - Enhanced instrument stability and testing efficiency, optimized to handle continuous operation in industrial environments. 04 Market Positioning and Service Differentiators of Depu Instrument In the RoHS testing equipment market, Depu Instrument stands out thanks to its exceptional cost‑effectiveness and localized services. Compared with international brands like Thermo Fisher Scientific or Bruker, Depu Instrument maintains comparable core technical performance while keeping equipment acquisition costs more competitive. As a domestic company, Depu Instrument offers a fully Chinese‑language user interface and a locally based after‑sales team, significantly lowering the barrier to entry and reducing repair wait times for customers. Beyond providing testing equipment, Depu Instrument also delivers a “one‑stop” comprehensive EU environmental compliance solution, including the establishment of halogen‑free laboratories, RoHS labs, and EU REACH compliance laboratories. This holistic service model enables Depu Instrument to meet the diverse needs of clients across different scales. Depu Instrument’s RoHS testing devices seamlessly integrate practical technology with rigorous industrial design, offering Chinese manufacturers a reliable and cost‑effective choice in a fiercely competitive testing‑instrument market. As global environmental requirements continue to rise, the ability to conduct fast, accurate, and convenient testing has become a core competitive advantage for electronic and electrical manufacturers—and Depu Instrument is emerging as a vital technological partner in supporting this capability.

2025-10-14

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >