[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Analysis of the application of atomic absorption spectrometers in food testing!
发布时间: 2022-11-22 10:40
Atomic absorption spectrometer It is a common… Spectroscopic instrument First, it has been widely applied in the detection of heavy metals in food. Below are several examples of how atomic absorption spectrometers are used in food analysis—those interested may wish to learn more!
1. Application Analysis in Fruit and Vegetable Products
Fruits and vegetables are among the most common foods in daily life; however, pesticide use during cultivation and environmental pollution of agricultural land have led to residual pesticide contamination in these products. Consequently, the detection of heavy metals in fruits and vegetables is essential. Atomic absorption spectrometry was employed to determine the levels of lead and cadmium in fruits and vegetables. The study found that automobile exhaust and coal‑combustion pollution can increase the concentrations of lead and cadmium in these commodities. Additionally, atomic absorption spectrometry was used to analyze the contents of chromium, lead, cadmium, and mercury in vegetables from a vegetable production base in Luoyang. The results indicated that lead is the predominant contaminant in the vegetables from this site, with root vegetables exhibiting lower contaminant levels than leafy vegetables. In this paper, lead and cadmium were selected as target elements, and ten types of fruits and vegetables—totaling 30 samples—were analyzed. The analytical results are presented in Table 1. As shown in the table, the concentrations of lead and cadmium vary significantly among different vegetable varieties: chrysanthemum exhibited the highest lead content, ranging from 0.094 to 0.12 mg/kg, while bitter melon recorded the highest cadmium levels, between 0.011 and 0.017 mg/kg. The measured values for lead and cadmium across the 30 fruit and vegetable samples were stable, sensitive, and reliable.
2. Application Analysis in Cereal Products
Currently, research on the determination of heavy metals in food by atomic absorption spectrometry has largely focused on methodological innovations and the identification of food contamination sources. For example, 29 infant and young‑child food products—both dairy‑containing and dairy‑free—were analyzed using an atomic absorption spectrometer, leading to the establishment of an effective analytical procedure for quantifying cadmium (Cd) and lead (Pb) levels in such foods. Parengam et al. employed instrumental neutron activation analysis (INAA) and graphite furnace atomic absorption spectrometry (GFAAS), respectively, to determine metal elements in rice and legumes. Comparative analyses revealed that INAA offers excellent accuracy and precision for aluminum, calcium, manganese, potassium, and other elements, with relative errors and relative standard deviations both below 10%. In contrast, GFAAS is better suited for the determination of lead and cadmium, with recovery rates exceeding 80% and relative errors of only 1.54% and 6.06%, respectively.
3. Application Analysis in Beverages
It is an important component of the food consumption market. As consumers’ demands for beverage quality and safety continue to rise, the detection of harmful metals has become a critical issue. In recent years, research in this field by experts and scholars has been steadily increasing. Using atomic spectrometers, the concentrations of 14 metal elements—including nickel, copper, chromium, cadmium, and lead—were determined in 120 commercially available coffee samples. The results indicated that the levels of certain metals in coffee exhibit specific correlations, providing a basis for identifying different coffee varieties. Carbonated beverage samples were subjected to pretreatment under specially optimized conditions, and the copper content was quantified using an atomic absorption spectrometer. The method achieved a detection limit of 0.265 μg/L, a linear range of 1.5–10 μg/L, a correlation coefficient of 0.9993, recoveries ranging from 95.79% to 100.74%, and relative standard deviations of 3.13% to 3.15%.
4. Application Analysis in Meat Products
The levels of heavy metal elements in nationally standardized meat products are also clearly specified. In addition to routine food safety monitoring, atomic absorption spectrometers can detect trace elements such as zinc, copper, iron, and calcium, enabling the assessment of the nutritional value of meat products. For example, numerous studies have employed atomic absorption spectroscopy to analyze differences in trace element content among Laiwu black pigs, wild boars, and conventional pork, thereby comparing their nutritional profiles. This technique is also widely used in the aquatic products sector, primarily for determining the zinc and copper concentrations in seafood.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.