What can an elemental analyzer measure?
发布时间: 2022-11-21 11:14
Elemental analyzer It refers to an instrument capable of analyzing several elements in a sample, either simultaneously or individually. So, what can an elemental analyzer measure? Let’s provide a brief answer below!
Although elemental analyzers vary in structure and performance, they are all designed based on chromatographic principles. Their operating principle involves oxidizing and combusting the sample at high temperature—under the action of a composite catalyst—to produce nitrogen, nitrogen oxides, carbon dioxide, sulfur dioxide, and water. These gases are then carried by a carrier gas into the separation and detection unit. Non‑nitrogen compounds are adsorbed and retained in the adsorption column, while nitrogen oxides are reduced to nitrogen and subsequently detected. Oxides of other elements are separated and quantified using adsorption–desorption columns, in the order of carbon, hydrogen, and sulfur. The presence of fluorine, phosphates, or large amounts of heavy metals in the sample can adversely affect the analytical results, and substances that are strongly acidic, strongly alkaline, or capable of generating explosive gases must not be analyzed with an elemental analyzer. Given the complex mineral composition and crystal structures of soil samples, to ensure the accuracy and stability of the measurement results, the sample particles must be thoroughly homogenized prior to analysis.
1. An elemental analyzer can analyze metallic elements!
Metal Element Analyzer It is a new-generation comprehensive analyzer developed in China. One instrument can simultaneously determine the total contents of carbon, sulfur, manganese, phosphorus, silicon, chromium, nickel, molybdenum, copper, titanium, vanadium, aluminum, tungsten, nitrogen, boron, magnesium, rare earth elements, and cobalt in carbon steels, alloy steels, stainless steels, gray cast iron, ductile cast iron, heat-resistant steels, and maraging steels. The system is controlled by a branded computer, equipped with an electronic balance, features a fully Chinese-language menu interface, and outputs results via a desktop printer.
II. The elemental analyzer can perform organic analysis!
As a routine laboratory instrument, the elemental analyzer enables the quantitative analysis and determination of carbon, hydrogen, nitrogen, sulfur, and other elements in organic solids, highly volatile substances, and sensitive materials, playing a crucial role in studying the elemental composition of organic substances and compounds. It finds broad applications in the chemical and pharmaceutical industries—such as in fine chemicals, pharmaceuticals, fertilizers, and petrochemical products—for measuring the contents of carbon, hydrogen, oxygen, and nitrogen, thereby revealing changes in compound properties and yielding valuable insights. It is an effective tool for scientific research.
The above is an introduction to what an elemental analyzer can measure. If you would like to learn more, please continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.