[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
On July 22, 2019, the EU’s RoHS 2.0 will be fully enforced.
分类: News Center
发布时间: 2021-05-27 16:23
RoHS 2.0 is an upgraded version of RoHS. It adds four phthalates to the list as the tenth substance, and, with the exception of Category 8 medical devices and Category 9 monitoring equipment, all other electrical and electronic equipment must comply by July 22, 2019.
The concentration limits for the restricted substances listed in RoHS 2.0 have also been revised; the specific revisions and their implementation dates are set out in Annex II of the RoHS 2.0 Directive.
|
Substance |
Maximum allowable concentration by weight |
Implementation Time |
|
Lead |
0.1% |
Classes 1–7 and Class 10: July 1, 2006 Classes 8 and 9: July 22, 2014 In vitro diagnostic medical devices: July 22, 2018 Industrial Monitoring Equipment: July 22, 2017 Category 11: July 22, 2019 |
|
Mercury |
0.1% |
|
|
Cadmium |
0.01% |
|
|
Hexavalent chromium |
0.1% |
|
|
Polybrominated biphenyls (PBB) |
0.1% |
|
|
Polydiphenyl ether (PDE) |
0.1% |
|
|
Di(2-ethylhexyl) phthalate (DEHP) |
0.1% |
Categories 1–7, 10, and 11: July 22, 2019 Categories 8 and 9: July 22, 2021 |
|
Butyl phthalate Benzyl ester |
0.1% |
|
|
Dibutyl phthalate ( DBP ) |
0.1% |
|
|
Diisobutyl phthalate (DIBP) |
0.1% |
The specific categories are as follows:
1. Large household appliances
2. Small household appliances
3. Information Technology and Telecommunications Equipment
4. User Equipment
5. Lighting Equipment
6. Power Tools
7. Toys, recreational and sports equipment
8. Medical Equipment
9. Monitoring and control instruments, including industrial measurement and control equipment
10. Automatic Distribution Equipment
11. Other electrical and electronic equipment not covered by the above categories
CE Marking:
Effective January 3, 2013, the European Union has incorporated RoHS compliance for electrical and electronic equipment into the requirements for the CE marking. Manufacturers must ensure that their products comply with RoHS when affixing the CE mark and prepare the corresponding declaration and technical documentation, which must be retained for a period of ten years.
Shenzhen Delptek Instrument Co., Ltd. is a high-tech enterprise specializing in the research, development, manufacturing, and sales of spectroscopic (XRF), chromatographic, and mass spectrometric products. The company has two wholly owned subsidiaries—Shenzhen Shengwangda Instrument Equipment Co., Ltd. and Shenzhen Dezewei Testing Technology Co., Ltd.—and holds controlling interests in Hong Kong Songsheng Electronics Co., Ltd. and the Longgang Wanda Industrial Park in Shenzhen. We boast an R&D team that combines X-ray fluorescence technology with expertise from German technical specialists, achieving outstanding results across diverse fields. Our spectroscopy, chromatography, and mass spectrometry instruments are widely applied in numerous industries. Website: http://www.delptek.cn/ Address: Building 8, Shangxiawei Entrepreneurship Industrial Park, Sha Jing Subdistrict, Bao’an District, Shenzhen Contact Information: Mobile: 18688929727 / 13751165856 Landline: 0755-66862188 Contacts: Ms. Liu, Mr. Yang E-mail: sell@delptek.cn
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.