[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Comprehensive Governance Plan for Volatile Organic Compounds in Key Industries: Annex 5
分类: News Center
发布时间: 2019-07-05 16:21
Attachment 5:
Key Inspection Points for VOCs Control in Oil Storage, Transportation, and Sales
|
Category |
Inspection stage |
Key Inspection Points |
|
Oil storage facility |
Hair oiling stage |
1. Do tanker trucks or railway tank cars use bottom-loading or top-immersion loading methods? 2. Gas–liquid ratio, pressure in the oil–gas collection system, etc. |
|
Oil and gas processing unit |
3. Is there an oil and gas treatment facility? 4. Monitoring frequency, vapor‑oil emission concentrations, vapor‑oil treatment efficiency, and inlet and outlet pressures. 5. The frequency and quantity of single-use adsorbent replacement, the regeneration cycle and replacement status of regenerable adsorbents, as well as the storage and disposal of spent adsorbents. |
|
|
Oil and Gas Collection System |
6. Frequency and concentration of leak detection. |
|
|
Gas station |
Refueling phase |
1. Whether an oil‑vapor recovery‑type fuel nozzle is used, whether the nozzle’s vapor collection hood is damaged, and whether station personnel ensure that the hood is tightly sealed against the gasoline tank filler neck during refueling (verify on-site or by reviewing video footage from the fueling area). 2. Verify whether an oil‑gas recovery vacuum pump is installed and whether it is operating (open the fuel dispenser cover to check if the equipment is running during refueling); also confirm that the oil‑gas recovery copper tubing is properly connected. 3. The frequency of inspections and the inspection results for the vapor–liquid ratio of fuel dispensers, the liquid resistance of the vapor‑recovery system pipelines, and the pressure of the vapor collection system. |
|
Oil unloading phase |
4. Inspect the connection of the oil‑unloading vapor recovery pipeline (review the video recording of the unloading process). 5. Does the oil-unloading area have a dedicated vapor‑recovery nozzle, and are there quick‑connect sealing fittings or ball valves? |
|
|
Oil storage phase |
6. Is there an electronic level gauge? 7. Check whether there are any air leaks at the oil unloading port, vapor recovery port, level gauge port, P/V valve, and associated piping, and whether there is a noticeable odor inside the manhole. |
|
|
Online Monitoring System |
8. Gas–liquid ratio, gas flow rate, pressure, alarm logs, etc. |
|
|
Oil and gas processing unit |
9. The service life and replacement quantity of disposable adsorbents, the regeneration cycle and replacement status of regenerable adsorbents, as well as the storage and disposal of spent adsorbents. |
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.