Attachment 4:

Key Inspection Points for VOCs Control in Industrial Enterprises

Source term

Inspection stage

Key Inspection Points

VOCs materials

Storage

Containers, packaging bags

1. Are containers or packaging bags covered and sealed to maintain airtightness when not in use? Are waste packaging containers that have contained VOC‑containing materials also covered and sealed?

2. Are containers or packaging bags stored indoors, or in a dedicated area equipped with a canopy, shade protection, and impermeable liners?

Volatile Organic Liquid Storage Tank

3. Whether the tank type is compatible with the true vapor pressure and volume of the stored material, and whether there are any defects such as damage, holes, or gaps.

4. Does the edge sealing of the internal floating roof tank employ high-efficiency sealing methods such as liquid‑immersed or mechanical shoe‑type seals?

5. Does the external floating-roof tank employ a double-seal system, with the primary seal being an efficient type such as a liquid‑immersed seal or a mechanical shoe‑type seal?

6. Are the openings (holes) in the floating roof tank’s pontoon attachments sealed tight (except for sampling, metering, routine inspections, maintenance, and other normal operations)?

7. Are fixed-roof tanks equipped with VOCs treatment facilities or a vapor‑phase equilibrium system?

8. Does the set pressure of the breather valve meet the specified requirements?

9. Are the accessory openings (ports) of fixed-roof tanks sealed tight (except for sampling, metering, routine inspections, maintenance, and other normal operations)?

Storage silos, material bins

10. Is the enclosure structure intact and completely sealed off from the surrounding space?

11. Are doors, windows, and other openings (apertures) kept closed? (Except for personnel, vehicles, equipment, and materials entering or exiting, as well as legally established exhaust stacks and ventilation outlets.)

VOCs Material Transfer and Transportation

Liquid VOCs materials

1. Whether pipeline‑sealed conveyance is employed, or whether sealed containers or tank trucks are used.

Powdered and granular VOCs materials

2. Whether pneumatic conveying equipment, tubular belt conveyors, screw conveyors, or other enclosed conveying systems are employed, or whether sealed packaging bags, containers, or tank trucks are used.

Loading of volatile organic liquids

3. Do automotive and rail transport operations employ bottom-loading or top-immersion loading methods?

4. Are VOC-containing waste gases collected and treated in a closed system, or routed to a vapor‑phase equilibrium system, based on the annual loading volume and the true vapor pressure of the loaded materials? For facilities equipped with vapor recovery systems, verify the amount of vapor recovered.

Unorganized VOC Emissions from the Process

VOCs material addition and discharge

1. Is the feeding process of liquid and powdered VOC-containing materials conducted in a closed system, or are local gas collection measures implemented? Are the exhaust gases routed to a VOCs exhaust gas collection and treatment system?

2. Is the unloading (discharge or release) process of VOC-containing materials conducted in a closed system, or are local gas collection measures implemented? Are the exhaust gases routed to a VOCs exhaust gas collection and treatment system?

Chemical Reaction Unit

3. Are the waste gases from feed purging, venting, and reaction off-gases discharged to the VOCs collection and treatment system?

4. Are the feed inlets, discharge outlets, maintenance access ports, agitator openings, sight glasses, and other openings on reaction equipment sealed when not in operation?

Separation and Purification Unit

5. Are the centrifugation, filtration, and drying processes conducted in closed equipment, within enclosed spaces, or under localized gas collection measures? Is the exhaust gas routed to a VOCs collection and treatment system?

6. Are exhaust gases emitted from other separation and purification processes routed to the VOCs collection and treatment system?

7. Is the mother liquor after separation and purification collected in a sealed system? Are the exhaust gases generated from the mother liquor storage tank(s) routed to the VOCs collection and treatment system?

Vacuum system

8. For systems employing dry vacuum pumps, is the vacuum exhaust routed to the VOCs waste gas collection and treatment system?

9. For systems employing liquid-ring (water-ring) vacuum pumps or water‑(water‑steam) jet vacuum pumps, verify whether the circulating tank(s) for the working fluid are sealed, and whether the vacuum exhaust and the exhaust from the circulating tank(s) are routed to the VOCs waste gas collection and treatment system.

Ingredient Processing and Product Packaging Process

10. For processing steps such as blending, mixing, grinding, granulation, slicing, and briquetting, as well as for the packaging (filling and repackaging) of VOC‑containing products, are closed‑system equipment used, or operations conducted within enclosed spaces, or localized gas collection measures implemented? Are exhaust gases routed to a VOCs exhaust gas collection and treatment system?

The use process of VOC-containing products

11. During processes such as blending, coating, printing, bonding, dyeing, drying, and cleaning, when products with a VOC content of 10% or higher are used, are closed‑system equipment employed, or operations conducted in enclosed spaces, or local exhaust ventilation measures implemented? Are the resulting waste gases routed to a VOCs collection and treatment system?

12. In the production processes of organic polymers (such as synthetic resins, synthetic rubbers, and synthetic fibers)—including blending/mixing, plasticizing/plasticization/melting, and processing/forming (e.g., extrusion, injection molding, compression molding, calendering, foaming, and fiber spinning)—are closed‑type equipment used, or are operations conducted in enclosed spaces, or are local exhaust ventilation measures implemented? Are the resulting waste gases routed to a VOCs collection and treatment system?

Other processes

13. During startup, shutdown, maintenance, and cleaning of equipment and pipelines containing VOC‑containing materials, are residual materials fully drained during the draining phase and collected in sealed containers? Are exhaust gases generated during the draining process, as well as those from cleaning and purging operations, routed to the VOCs collection and treatment system?

VOCs Unorganized Waste Gas Collection and Treatment System

14. Whether it operates in synchronization with the production process equipment.

15. For systems employing external capture hoods, the control air velocity at the farthest point from the hood opening where VOCs are emitted in an uncontrolled manner shall be no less than 0.3 m/s (where specific industry requirements exist, compliance shall follow the relevant provisions).

16. Is the exhaust gas collection system operated under negative pressure? If it is under positive pressure, are there any leaks?

17. Are the conveyance pipelines of the exhaust gas collection system sealed and free from damage?

Equipment and Piping Component Leaks

LDAR work

1. For enterprises with 2,000 or more sealing points, is LDAR implementation being carried out?

2. Are pumps, compressors, agitators, valves, flanges, and other equipment subjected to leak detection at the prescribed frequency?

3. If visible leakage is detected or the concentration exceeds the established threshold for identifying a leak, is the source of the leak repaired within the prescribed timeframe?

4. During on-site random inspections, if, among no more than 100 sealed points inspected, two or more (excluding two) are found to exhibit visible leakage or exceed the established leakage threshold, such conduct shall be deemed a violation of the law.

VOC Emissions from Open Liquid Surfaces

Wastewater Collection and Transportation System

1. Is closed‑pipeline conveyance employed? If open‑channel conveyance is used without a sealed cover, does the VOC concentration measured above the wastewater surface exceed the regulatory limit?

2. Have the inlet and outlet been equipped with measures to isolate them from ambient air?

Wastewater storage,

Treatment facility

3. For wastewater storage and treatment facilities that are open to the atmosphere, verify whether the VOCs concentration measured above the liquid surface exceeds the regulatory limit.

4. For systems with fixed roof covers, is the exhaust gas collected and routed to a VOCs collection and treatment system?

Open-loop cooling water system

5. Is the TOC or POC concentration in the circulating cooling water at the inlet and outlet of the heat exchanger tested every six months? Are any leaks promptly repaired and documented?

Organized VOC Emissions

Exhaust stack

1. Is the VOCs emission concentration stable and compliant with regulatory standards?

2. For exhaust gases collected and emitted from workshops or production facilities, if the initial VOC emission rate is greater than or equal to 3 kg/hour, or greater than or equal to 2 kg/hour in key areas, verify whether the VOC control efficiency meets the required standards; except where the raw and auxiliary materials used comply with national regulations on low-VOC-content products.

3. Whether automatic monitoring facilities have been installed, whether such facilities are operating normally, and whether they are connected to the ecological and environmental authorities.

Exhaust gas treatment

Facilities

Cooler/Condenser

1. Does the outlet temperature meet the design requirements?

2. Is there a situation where the outlet temperature exceeds the inlet temperature of the cooling medium?

3. Solvent recovery rate of the condenser.

Adsorption device

4. Types of adsorbents and their packing conditions.

5. Single-use adsorbent replacement interval and replacement quantity.

6. Regeneration cycle and replacement status of the regenerative adsorbent.

7. Storage and disposal of spent adsorbents.

Catalytic Oxidizer

8. Catalytic (bed) temperature.

9. Electricity or natural gas consumption.

10. Catalyst replacement cycle and replacement status.

Thermal Oxidizer

11. Does the combustion temperature meet the design requirements?

Scrubber/Absorption Tower

12. For acid–base control absorption towers, verify the pH of the scrubbing/absorption liquid.

13. Dosage and dosing interval of the chemical agent.

14. Replacement cycle and replacement volume of the washing/absorption solution.

15. For oxidation‑reaction absorption towers, verify the oxidation‑reduction potential (ORP) value.

Ledger

Does the enterprise maintain records in accordance with the requirements?

Latest News

Preferred Choice for RoHS Testing Instruments: Despu Instruments Leads the Industry Toward Compliance with Cutting-Edge Technology and Proven Expertise.

Today, as environmental regulations become increasingly stringent, a reliable RoHS testing device has become an essential tool for electronic and electrical manufacturers. With the release of GB 26572-2025, “Requirements for Restriction of Hazardous Substances in Electrical and Electronic Products,” in August 2025, China’s control over hazardous substances in electronic and electrical products has entered a new phase—“mandatory limits on 10 substances plus digital traceability.” Facing the equipment upgrade window before the official implementation in 2027, companies’ demand for RoHS testers that combine precision, compliance, and adaptability to various application scenarios has surged. Among numerous suppliers, Shenzhen Depu Instrument Co., Ltd. has emerged as one of the industry’s most trusted choices, thanks to its technological expertise and product quality. 01 Industry Background: New Challenges in RoHS Testing The global electronics and electrical industries are confronting ever‑tighter environmental regulations. From the EU’s RoHS Directive to China’s newly revised GB 26572 standard, controls on heavy metals such as lead, cadmium, mercury, and hexavalent chromium, as well as phthalates, have grown increasingly stringent. Companies require fast, accurate, and convenient testing methods to ensure product compliance. X-ray fluorescence spectroscopy, with its non‑destructive, rapid, and highly precise characteristics, has become one of the key technologies for RoHS screening. 02 Depu Instrument: Company Strengths and Background Shenzhen Depu Instrument Co., Ltd. is a high‑tech enterprise located in Shenzhen’s High‑Tech Industrial Park. Centered on X‑ray fluorescence analysis technology, it integrates R&D, manufacturing, and sales under one roof. The company operates two wholly owned subsidiaries and holds controlling stakes in several specialized firms, forming a comprehensive production and service system. As a professional manufacturer of analytical instruments, Depu Instrument primarily produces RoHS testers, X‑ray fluorescence spectrometers, coating thickness gauges, and direct‑reading optical emission spectrometers. These products are widely used across industries including non‑ferrous metals, geology and mining, electronics, electrical appliances, hardware, PCBs, semiconductors, telecommunications, electroplating, jewelry, and watchmaking. 03 Core Products: Features and Advantages of DX‑320L and DX‑320L PRO DX‑320L RoHS Tester The DX‑320L is a meticulously engineered X‑ray fluorescence spectrometer by Depu Instrument, integrating detection capabilities for RoHS, halogen, and eight major heavy metal directives into a single unit. **Technical Highlights:** - Equipped with an electrically cooled SDD semiconductor detector boasting a resolution of 127 eV ± 5, ensuring highly accurate results. - Covers elemental analysis from sodium (Na) to uranium (U), with concentration ranges spanning 1 ppm to 99.99%. - Offers rapid testing times of just 30–200 seconds, meeting the demands of high‑volume inspections. - Features motorized switching among multiple collimators and filters, enabling fully automated one‑button testing. **Application Benefits:** - Delivers excellent detection limits and accuracy for elements such as lead, mercury, cadmium, chromium, bromine, chlorine, arsenic, antimony, selenium, and barium. - Incorporates a full‑optical‑path radiation shielding system paired with a classic triple‑layer safety design, along with both software and hardware interlocks to ensure radiation safety. - Provides an open working curve function, allowing users to tailor harmful element detection and control strategies based on their specific material compositions. Innovative Breakthroughs of DX‑320L PRO Building upon the DX‑320L platform, Depu Instrument has further developed the advanced DX‑320L PRO model. Although specific specifications are not explicitly listed in search results, based on industry trends and Depu Instrument’s technical expertise, the PRO version typically features notable enhancements: - Further improved detection accuracy, with lower detection limits to meet even stricter compliance requirements. - Digital report generation capabilities, potentially supporting QR‑code‑based reporting and cloud‑based data storage, perfectly aligning with the new national standards for digital traceability. - Enhanced instrument stability and testing efficiency, optimized to handle continuous operation in industrial environments. 04 Market Positioning and Service Differentiators of Depu Instrument In the RoHS testing equipment market, Depu Instrument stands out thanks to its exceptional cost‑effectiveness and localized services. Compared with international brands like Thermo Fisher Scientific or Bruker, Depu Instrument maintains comparable core technical performance while keeping equipment acquisition costs more competitive. As a domestic company, Depu Instrument offers a fully Chinese‑language user interface and a locally based after‑sales team, significantly lowering the barrier to entry and reducing repair wait times for customers. Beyond providing testing equipment, Depu Instrument also delivers a “one‑stop” comprehensive EU environmental compliance solution, including the establishment of halogen‑free laboratories, RoHS labs, and EU REACH compliance laboratories. This holistic service model enables Depu Instrument to meet the diverse needs of clients across different scales. Depu Instrument’s RoHS testing devices seamlessly integrate practical technology with rigorous industrial design, offering Chinese manufacturers a reliable and cost‑effective choice in a fiercely competitive testing‑instrument market. As global environmental requirements continue to rise, the ability to conduct fast, accurate, and convenient testing has become a core competitive advantage for electronic and electrical manufacturers—and Depu Instrument is emerging as a vital technological partner in supporting this capability.

2025-10-14

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with answers to frequently asked questions. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >