[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Comprehensive Governance Plan for Volatile Organic Compounds in Key Industries: Annexes 1–3
分类: News Center
发布时间: 2019-07-05 16:04
Attachment 1:
Scope of Key Areas
|
Region Name |
Scope |
|
Beijing–Tianjin–Hebei and surrounding areas |
Beijing Municipality, Tianjin Municipality, and the cities of Shijiazhuang, Tangshan, Handan, Xingtai, Baoding, Cangzhou, Langfang, and Hengshui in Hebei Province, as well as the Xiongan New Area; Taiyuan, Yangquan, Changzhi, and Jincheng in Shanxi Province; Jinan, Zibo, Jining, Dezhou, Liaocheng, Binzhou, and Heze in Shandong Province; and Zhengzhou, Kaifeng, Anyang, Hebi, Xinxiang, Jiaozuo, and Puyang in Henan Province (including Dingzhou and Xinji Cities in Hebei Province, and Jiyuan City in Henan Province). |
|
Yangtze River Delta region |
Shanghai Municipality, Jiangsu Province, Zhejiang Province, Anhui Province |
|
Fenwei Plain |
Jinzhong, Yuncheng, Linfen, and Lüliang cities in Shanxi Province; Luoyang and Sanmenxia cities in Henan Province; Xi’an, Tongchuan, Baoji, Xianyang, and Weinan cities in Shaanxi Province, as well as the Yangling Demonstration Zone (including the Xixian New Area of Shaanxi Province and Hancheng City). |
Attachment 2:
Key VOCs substances under control
|
Category |
Key VOCs substances under control |
|
O3 precursor |
o-/p-xylene, ethylene, propylene, formaldehyde, toluene, acetaldehyde, 1,3-butadiene, trimethylbenzene, o-xylene, styrene, and others |
|
PM2.5 precursors |
Toluene, n-dodecane, m-/p-xylene, styrene, n-undecane, n-decane, ethylbenzene, o-xylene, 1,3-butadiene, methylcyclohexane, n-nonane, and others |
|
Malodorous substances |
Methylamines, methyl mercaptan, methyl sulfide, dimethyl disulfide, carbon disulfide, styrene, cumene, phenol, acrylates, and others. |
|
Highly toxic substances |
Benzene, formaldehyde, vinyl chloride, trichloroethylene, acrylonitrile, acrylamide, ethylene oxide, 1,2-dichloroethane, isocyanates, and others |
Attachment 3:
Requirements for Record-Keeping in VOCs Management
|
Key points Industry |
Key links |
Record-keeping requirements |
|
Petrochemical/ Chemical industry |
VOC-containing raw and auxiliary materials |
Names of VOC‑containing raw and auxiliary materials and their VOC content, along with procurement quantities, usage volumes, and inventory levels; as well as the methods for recovering VOC‑containing raw and auxiliary materials and the corresponding recovery volumes. |
|
Sealed point |
Detection time, leak detection concentration, repair time, remedial measures taken, and post-repair leak detection concentration, among others. |
|
|
Organic liquid storage |
Name of the organic liquid material, tank type and sealing method, storage temperature, turnover volume, and vapor recovery volume, among others. |
|
|
Organic liquid loading |
Names of organic liquid materials, loading methods, loading quantities, and vapor recovery volumes, among others. |
|
|
Wastewater Collection, Transportation, Storage, and Treatment |
Wastewater volume, wastewater collection and conveyance methods (closed pipelines, open channels), the degree of enclosure of wastewater treatment facilities, and the measured VOC concentrations above the surface of open liquid pools, among other factors. |
|
|
Recirculating water system |
Detection time, TOC or POC concentrations at the inlet and outlet of the circulating water tower, TOC or POC concentrations at the inlet and outlet of heat exchangers handling VOC‑containing materials, remediation duration, remediation measures, and TOC or POC concentrations at the inlet and outlet after remediation, among others. |
|
|
Emissions under abnormal operating conditions (including start-up, shutdown, and maintenance) |
Start-up and shutdown schedules, maintenance and inspection periods, the recovery of VOC‑containing materials during material return, purging, and cleaning operations, the collection and treatment of VOC‑emitting exhaust gases, as well as the volume and collection status of highly volatile non‑conforming products generated during the start-up phase. |
|
|
Torch Emission |
Torch operating time, fuel consumption, flare gas flow rate, and other parameters. |
|
|
Accidental discharge |
Accident category, time, response measures, and other relevant details. |
|
|
Exhaust Gas Collection and Treatment Facility |
Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.). |
|
|
Key parameters of exhaust gas collection and treatment facilities (see Annex 4). |
||
|
Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.). |
||
|
Industrial Coating |
Production Information |
Basic production information, including the output of major products and the total coated area. |
|
VOC-containing raw and auxiliary materials |
Names of VOC‑containing raw and auxiliary materials (such as coatings, curing agents, thinners, adhesives, cleaning agents, etc.) and their VOC content; procurement volume, usage volume, and inventory levels; as well as the methods for recovering VOC‑containing raw and auxiliary materials and the corresponding recovery volumes. |
|
|
Exhaust Gas Collection and Treatment Facility |
Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.). |
|
|
Key parameters of exhaust gas collection and treatment facilities (see Annex 4). |
||
|
Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.). |
||
|
Packaging and Printing |
Production Information |
Basic production information, including the print run of the main product. |
|
VOC-containing raw and auxiliary materials |
Names of VOC‑containing raw and auxiliary materials (such as inks, thinners, cleaning agents, fountain solutions, adhesives, laminating adhesives, varnishes, coatings, etc.), along with their VOC content; procurement quantities, usage volumes, and inventory levels; as well as the methods and quantities of recovery for these VOC‑containing materials. |
|
|
Exhaust Gas Collection and Treatment Facility |
Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.). |
|
|
Key parameters of exhaust gas collection and treatment facilities (see Annex 4). |
||
|
Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.). |
||
|
Oil storage facility |
Basic Information |
Types of oil products, turnover volume, and so on. |
|
Oil receiving and dispatching |
Oil receipt and dispatch times, types and quantities of oil, and sources of the oil; gas–liquid ratio measurement times and results, remediation times, and the remediation measures implemented; as well as pressure measurement times and results for the vapor‑oil collection system, remediation times, and the remediation measures adopted. |
|
|
Oil and gas processing unit |
Inlet pressure, temperature, and flow rate; outlet concentration, pressure, temperature, and flow rate; repair time and the remedial measures implemented; as well as the service life and quantity of single-use adsorbents, the regeneration cycle and replacement status of regenerable adsorbents, and the storage and disposal of spent adsorbents. |
|
|
Leakage point |
Testing methods, test results, repair time, corrective measures taken, and post-repair test results, among others. |
|
|
Gas station |
Basic Information |
Types of oil, sales volume, and so on. |
|
Refueling process |
Gas–liquid ratio testing: test duration and results, repair duration, and corrective measures implemented; vapor‑gas recovery system pipeline hydraulic resistance testing: test duration and results, repair duration, and corrective measures implemented; vapor‑gas recovery system leak‑tightness testing: test duration and results, repair duration, and corrective measures implemented. |
|
|
Oil unloading process |
Oil unloading time, oil type, oil origin, unloading volume, and unloading method, among others. |
|
|
Oil and gas processing unit |
The frequency and quantity of single-use adsorbent replacement, the regeneration cycle and replacement status of regenerable adsorbents, as well as the storage and disposal of spent adsorbents, etc. |
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
