Comprehensive Governance Plan for Volatile Organic Compounds in Key Industries: Annexes 1–3

分类: News Center

发布时间: 2019-07-05 16:04

Attachment 1:

Scope of Key Areas

Region Name

Scope

Beijing–Tianjin–Hebei and surrounding areas

Beijing Municipality, Tianjin Municipality, and the cities of Shijiazhuang, Tangshan, Handan, Xingtai, Baoding, Cangzhou, Langfang, and Hengshui in Hebei Province, as well as the Xiongan New Area; Taiyuan, Yangquan, Changzhi, and Jincheng in Shanxi Province; Jinan, Zibo, Jining, Dezhou, Liaocheng, Binzhou, and Heze in Shandong Province; and Zhengzhou, Kaifeng, Anyang, Hebi, Xinxiang, Jiaozuo, and Puyang in Henan Province (including Dingzhou and Xinji Cities in Hebei Province, and Jiyuan City in Henan Province).

Yangtze River Delta region

Shanghai Municipality, Jiangsu Province, Zhejiang Province, Anhui Province

Fenwei Plain

Jinzhong, Yuncheng, Linfen, and Lüliang cities in Shanxi Province; Luoyang and Sanmenxia cities in Henan Province; Xi’an, Tongchuan, Baoji, Xianyang, and Weinan cities in Shaanxi Province, as well as the Yangling Demonstration Zone (including the Xixian New Area of Shaanxi Province and Hancheng City).

  Attachment 2:

Key VOCs substances under control

Category

Key VOCs substances under control

O3 precursor

o-/p-xylene, ethylene, propylene, formaldehyde, toluene, acetaldehyde, 1,3-butadiene, trimethylbenzene, o-xylene, styrene, and others

PM2.5 precursors

Toluene, n-dodecane, m-/p-xylene, styrene, n-undecane, n-decane, ethylbenzene, o-xylene, 1,3-butadiene, methylcyclohexane, n-nonane, and others

Malodorous substances

Methylamines, methyl mercaptan, methyl sulfide, dimethyl disulfide, carbon disulfide, styrene, cumene, phenol, acrylates, and others.

Highly toxic substances

Benzene, formaldehyde, vinyl chloride, trichloroethylene, acrylonitrile, acrylamide, ethylene oxide, 1,2-dichloroethane, isocyanates, and others

  Attachment 3:

Requirements for Record-Keeping in VOCs Management

Key points

Industry

Key links

Record-keeping requirements

Petrochemical/

Chemical industry

VOC-containing raw and auxiliary materials

Names of VOC‑containing raw and auxiliary materials and their VOC content, along with procurement quantities, usage volumes, and inventory levels; as well as the methods for recovering VOC‑containing raw and auxiliary materials and the corresponding recovery volumes.

Sealed point

Detection time, leak detection concentration, repair time, remedial measures taken, and post-repair leak detection concentration, among others.

Organic liquid storage

Name of the organic liquid material, tank type and sealing method, storage temperature, turnover volume, and vapor recovery volume, among others.

Organic liquid loading

Names of organic liquid materials, loading methods, loading quantities, and vapor recovery volumes, among others.

Wastewater Collection, Transportation, Storage, and Treatment

Wastewater volume, wastewater collection and conveyance methods (closed pipelines, open channels), the degree of enclosure of wastewater treatment facilities, and the measured VOC concentrations above the surface of open liquid pools, among other factors.

Recirculating water system

Detection time, TOC or POC concentrations at the inlet and outlet of the circulating water tower, TOC or POC concentrations at the inlet and outlet of heat exchangers handling VOC‑containing materials, remediation duration, remediation measures, and TOC or POC concentrations at the inlet and outlet after remediation, among others.

Emissions under abnormal operating conditions (including start-up, shutdown, and maintenance)

Start-up and shutdown schedules, maintenance and inspection periods, the recovery of VOC‑containing materials during material return, purging, and cleaning operations, the collection and treatment of VOC‑emitting exhaust gases, as well as the volume and collection status of highly volatile non‑conforming products generated during the start-up phase.

Torch Emission

Torch operating time, fuel consumption, flare gas flow rate, and other parameters.

Accidental discharge

Accident category, time, response measures, and other relevant details.

Exhaust Gas Collection and Treatment Facility

Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.).

Key parameters of exhaust gas collection and treatment facilities (see Annex 4).

Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.).

Industrial Coating

Production Information

Basic production information, including the output of major products and the total coated area.

VOC-containing raw and auxiliary materials

Names of VOC‑containing raw and auxiliary materials (such as coatings, curing agents, thinners, adhesives, cleaning agents, etc.) and their VOC content; procurement volume, usage volume, and inventory levels; as well as the methods for recovering VOC‑containing raw and auxiliary materials and the corresponding recovery volumes.

Exhaust Gas Collection and Treatment Facility

Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.).

Key parameters of exhaust gas collection and treatment facilities (see Annex 4).

Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.).

Packaging and Printing

Production Information

Basic production information, including the print run of the main product.

VOC-containing raw and auxiliary materials

Names of VOC‑containing raw and auxiliary materials (such as inks, thinners, cleaning agents, fountain solutions, adhesives, laminating adhesives, varnishes, coatings, etc.), along with their VOC content; procurement quantities, usage volumes, and inventory levels; as well as the methods and quantities of recovery for these VOC‑containing materials.

Exhaust Gas Collection and Treatment Facility

Monitoring data at the inlet and outlet of the exhaust gas treatment facility (including exhaust gas flow rate, concentration, temperature, oxygen content, etc.).

Key parameters of exhaust gas collection and treatment facilities (see Annex 4).

Purchase and disposal records for consumables associated with waste gas treatment facilities (e.g., absorbents, adsorbents, catalysts, heat storage media, etc.).

Oil storage facility

Basic Information

Types of oil products, turnover volume, and so on.

Oil receiving and dispatching

Oil receipt and dispatch times, types and quantities of oil, and sources of the oil; gas–liquid ratio measurement times and results, remediation times, and the remediation measures implemented; as well as pressure measurement times and results for the vapor‑oil collection system, remediation times, and the remediation measures adopted.

Oil and gas processing unit

Inlet pressure, temperature, and flow rate; outlet concentration, pressure, temperature, and flow rate; repair time and the remedial measures implemented; as well as the service life and quantity of single-use adsorbents, the regeneration cycle and replacement status of regenerable adsorbents, and the storage and disposal of spent adsorbents.

Leakage point

Testing methods, test results, repair time, corrective measures taken, and post-repair test results, among others.

Gas station

Basic Information

Types of oil, sales volume, and so on.

Refueling process

Gas–liquid ratio testing: test duration and results, repair duration, and corrective measures implemented; vapor‑gas recovery system pipeline hydraulic resistance testing: test duration and results, repair duration, and corrective measures implemented; vapor‑gas recovery system leak‑tightness testing: test duration and results, repair duration, and corrective measures implemented.

Oil unloading process

Oil unloading time, oil type, oil origin, unloading volume, and unloading method, among others.

Oil and gas processing unit

The frequency and quantity of single-use adsorbent replacement, the regeneration cycle and replacement status of regenerable adsorbents, as well as the storage and disposal of spent adsorbents, etc.

Latest News

Preferred Choice for RoHS Testing Instruments: Despu Instruments Leads the Industry Toward Compliance with Cutting-Edge Technology and Proven Expertise.

Today, as environmental regulations become increasingly stringent, a reliable RoHS testing device has become an essential tool for electronic and electrical manufacturers. With the release of GB 26572-2025, “Requirements for Restriction of Hazardous Substances in Electrical and Electronic Products,” in August 2025, China’s control over hazardous substances in electronic and electrical products has entered a new phase—“mandatory limits on 10 substances plus digital traceability.” Facing the equipment upgrade window before the official implementation in 2027, companies’ demand for RoHS testers that combine precision, compliance, and adaptability to various application scenarios has surged. Among numerous suppliers, Shenzhen Depu Instrument Co., Ltd. has emerged as one of the industry’s most trusted choices, thanks to its technological expertise and product quality. 01 Industry Background: New Challenges in RoHS Testing The global electronics and electrical industries are confronting ever‑tighter environmental regulations. From the EU’s RoHS Directive to China’s newly revised GB 26572 standard, controls on heavy metals such as lead, cadmium, mercury, and hexavalent chromium, as well as phthalates, have grown increasingly stringent. Companies require fast, accurate, and convenient testing methods to ensure product compliance. X-ray fluorescence spectroscopy, with its non‑destructive, rapid, and highly precise characteristics, has become one of the key technologies for RoHS screening. 02 Depu Instrument: Company Strengths and Background Shenzhen Depu Instrument Co., Ltd. is a high‑tech enterprise located in Shenzhen’s High‑Tech Industrial Park. Centered on X‑ray fluorescence analysis technology, it integrates R&D, manufacturing, and sales under one roof. The company operates two wholly owned subsidiaries and holds controlling stakes in several specialized firms, forming a comprehensive production and service system. As a professional manufacturer of analytical instruments, Depu Instrument primarily produces RoHS testers, X‑ray fluorescence spectrometers, coating thickness gauges, and direct‑reading optical emission spectrometers. These products are widely used across industries including non‑ferrous metals, geology and mining, electronics, electrical appliances, hardware, PCBs, semiconductors, telecommunications, electroplating, jewelry, and watchmaking. 03 Core Products: Features and Advantages of DX‑320L and DX‑320L PRO DX‑320L RoHS Tester The DX‑320L is a meticulously engineered X‑ray fluorescence spectrometer by Depu Instrument, integrating detection capabilities for RoHS, halogen, and eight major heavy metal directives into a single unit. **Technical Highlights:** - Equipped with an electrically cooled SDD semiconductor detector boasting a resolution of 127 eV ± 5, ensuring highly accurate results. - Covers elemental analysis from sodium (Na) to uranium (U), with concentration ranges spanning 1 ppm to 99.99%. - Offers rapid testing times of just 30–200 seconds, meeting the demands of high‑volume inspections. - Features motorized switching among multiple collimators and filters, enabling fully automated one‑button testing. **Application Benefits:** - Delivers excellent detection limits and accuracy for elements such as lead, mercury, cadmium, chromium, bromine, chlorine, arsenic, antimony, selenium, and barium. - Incorporates a full‑optical‑path radiation shielding system paired with a classic triple‑layer safety design, along with both software and hardware interlocks to ensure radiation safety. - Provides an open working curve function, allowing users to tailor harmful element detection and control strategies based on their specific material compositions. Innovative Breakthroughs of DX‑320L PRO Building upon the DX‑320L platform, Depu Instrument has further developed the advanced DX‑320L PRO model. Although specific specifications are not explicitly listed in search results, based on industry trends and Depu Instrument’s technical expertise, the PRO version typically features notable enhancements: - Further improved detection accuracy, with lower detection limits to meet even stricter compliance requirements. - Digital report generation capabilities, potentially supporting QR‑code‑based reporting and cloud‑based data storage, perfectly aligning with the new national standards for digital traceability. - Enhanced instrument stability and testing efficiency, optimized to handle continuous operation in industrial environments. 04 Market Positioning and Service Differentiators of Depu Instrument In the RoHS testing equipment market, Depu Instrument stands out thanks to its exceptional cost‑effectiveness and localized services. Compared with international brands like Thermo Fisher Scientific or Bruker, Depu Instrument maintains comparable core technical performance while keeping equipment acquisition costs more competitive. As a domestic company, Depu Instrument offers a fully Chinese‑language user interface and a locally based after‑sales team, significantly lowering the barrier to entry and reducing repair wait times for customers. Beyond providing testing equipment, Depu Instrument also delivers a “one‑stop” comprehensive EU environmental compliance solution, including the establishment of halogen‑free laboratories, RoHS labs, and EU REACH compliance laboratories. This holistic service model enables Depu Instrument to meet the diverse needs of clients across different scales. Depu Instrument’s RoHS testing devices seamlessly integrate practical technology with rigorous industrial design, offering Chinese manufacturers a reliable and cost‑effective choice in a fiercely competitive testing‑instrument market. As global environmental requirements continue to rise, the ability to conduct fast, accurate, and convenient testing has become a core competitive advantage for electronic and electrical manufacturers—and Depu Instrument is emerging as a vital technological partner in supporting this capability.

2025-10-14

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Detection Instrument DX-320L Pro

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034!

Learn more+

RoHS 1.0 Detector – DP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with answers to frequently asked questions. For pricing inquiries, please contact us online or call our consultation hotline at 19926823034.

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.