Features of the Soil and Grain Heavy Metal Analyzer!

发布时间: 2022-11-09 10:35

Soil and Grain Heavy Metal Analyzer What are its characteristics? Many people are probably curious—below, we’ve compiled a few key points for your reference!


1. The soil and grain heavy metal analyzer is easy to use, featuring a user-friendly interface and robust data management. It enables multi-element analysis of soil powders, including cadmium, arsenic, mercury, lead, chromium, copper, nickel, zinc, manganese, cobalt, selenium, vanadium, antimony, and molybdenum. Suitable for a wide range of applications, it provides quantitative determination of heavy metal concentrations—such as cadmium—in soils and powdered samples.

II. Based on HDXRF technology, it is possible to rapidly and accurately quantify heavy metals such as cadmium in soil. Its superior analytical performance meets the requirements of China’s agricultural soil regulations—its detection limit easily satisfies the regulatory threshold of 0.3 mg/kg for cadmium. Furthermore, it can also measure other heavy metals—including arsenic, lead, copper, nickel, and selenium—in agricultural products like rice and wheat. Whether you are an agricultural‑product analyst or an environmental assessor, this capability enables you to process more samples in less time and conduct more comprehensive analyses, thereby enhancing your ability to make informed decisions regarding on-site land remediation and land classification and grading.

3. Given the complexity of soil matrices, national standard reference materials for soils and sediments were selected to directly analyze cadmium (Cd) content. Instrumental accuracy was evaluated by assessing the relative error between measured values and certified reference values. HDXRF delivers accurate results across both high and low cadmium concentrations, including levels below the regulatory threshold of 0.3 ppm.

4. Not only does it deliver outstanding performance in detecting heavy metal contaminants in soils with complex matrices, but it also achieves excellent accuracy when measuring other powdered samples such as rice. Repeated measurements of rice reference materials demonstrate that the method’s quantitation limit is below the regulatory threshold of 0.2 ppm, and Cadence’s analytical performance is comparable to that of wet‑chemical methods.

V. Adoption of High-Definition X-ray Fluorescence (HDXRF) Technology: Compared with conventional energy-dispersive X-ray fluorescence (EDXRF) technology, HDXRF delivers significantly improved analytical performance. This technology employs advanced monochromatic and focusing optics, substantially enhancing the signal-to-noise ratio.

VI. Basic Configuration of HDXRF and the Principle of Monochromatic Light Focusing Excitation. In this system, a double‑curved crystal (DCC) optical element converts polychromatic radiation from the source into monochromatic light and efficiently focuses it onto a small area of the sample being measured.

7. The focused monochromatic beam of the sample is excited to emit fluorescent X-rays. The detector processes the signal to determine the elemental composition of the sample.

In summary, the soil and grain heavy-metal analyzer is suitable for analyzing heavy metals in both soil and food. Based on HDXRF technology, it enables quantitative determination of cadmium levels in soils and agricultural products, with detection limits so low that they meet the maximum residue limits stipulated by Chinese agricultural regulations. The instrument is easy to use, portable, lightweight, and capable of multi-element analysis, making it applicable across a wide range of fields, while requiring simple sample preparation.

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.