发布时间: 2022-11-09 10:27
Fluorescence refers to the phenomenon of cold light emission induced by illumination. When a substance at room temperature is irradiated with incident light of a specific wavelength—typically ultraviolet or X-rays—it absorbs energy and transitions to an excited state, then immediately relaxes, emitting emitted light with a longer wavelength than the incident light (usually in the visible spectrum). Moreover, once the incident light is removed, the luminescence ceases immediately. The emitted light exhibiting these characteristics is called fluorescence. In everyday life, people often use the term “fluorescence” to refer collectively to various forms of weak light. Fluorescence analyzer It consists of a light source, a monochromator (filter or grating), slits, a sample chamber, a signal detection and amplification system, and a signal readout and recording system. The light source excites the sample, the monochromator isolates the desired monochromatic light, the signal detection and amplification system converts the fluorescence signal into an electrical signal, and the readout device—connected to the amplifier—displays or records the fluorescence signal. Next, let’s discuss the applications of fluorescence analyzers; those interested may wish to learn more!

Applications of the fluorescence analyzer:
Analysis of trace elements and trace harmful elements in metals within the metallurgical industry:
Environmental protection; analysis of trace heavy metals in air and water;
Analysis of trace elements in resin films used in the metal manufacturing industry;
Analysis of trace elements harmful to human health in the precious metals industry;
Analysis of trace elements in the rare earth industry;
Analysis of sub-nanometer-thick metal coatings in the metal coating industry;
Analysis of Trace Elements Harmful to Human Health in Foreign Trade:
Analysis of eight trace metal elements in the toy export industry;
The primary feature of the fluorescence analyzer is its ability to excite light elements such as silicon, phosphorus, sulfur, aluminum, and magnesium. By employing an intelligent vacuum system, XRF technology can accurately analyze critical elements like chromium, nickel, and molybdenum, even at high concentrations, thereby significantly reducing analysis time and greatly enhancing detection efficiency and operational productivity in metallurgical process control. The fluorescence analyzer enables both qualitative and quantitative analysis of solid, liquid, and powdered samples at any time. Its products are widely used in aerospace, petrochemicals, mechanical manufacturing, power generation, pressure vessel inspection, specialized testing institutions, electronics and electrical appliances, material recycling, environmental soil monitoring, as well as in geological and mineral exploration, archaeology, food safety, customs inspections, and many other fields.
The above is an introduction to the applications of fluorescence analyzers. If you would like to learn more, please continue browsing. Fluorescence Analyzer Information Section If you’d like to learn more about our products, feel free to contact us online or by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.