Principle, Procedure, and Precautions for Heavy Metal Detectors!
发布时间: 2022-11-07 11:04
Heavy metal detector It consists primarily of a metal detector and an automatic rejection device, with the detector serving as the core component. The detector incorporates three sets of coils: a central transmitting coil and two identical receiving coils. An oscillator connected to the central transmitting coil generates a high‑frequency, variable magnetic field. In the absence of any foreign objects, the induced voltages in the two receiving coils cancel each other out, maintaining electrical balance. When metallic contaminants enter the magnetic field, the field is perturbed, disrupting this balance; the induced voltages in the receiving coils can no longer cancel one another. The residual voltage is amplified by the control system, triggering an alarm signal that indicates the presence of metallic contamination. This system can use the alarm signal to activate the automatic rejection mechanism, thereby removing metallic impurities from the production line. Next, we will explain the detection principle, operational procedure, and key considerations for heavy‑metal detectors.
I. Principle of Operation of Heavy Metal Detectors:
After digestion, all forms of heavy metals in the sample are converted to their ionic forms, and a suitable reagent is added to produce a color change. Within a certain concentration range, the intensity of the solution’s color is directly proportional to the heavy metal content. The heavy metal concentration is then determined using an instrument and compared with the national standards for agricultural product safety and quality as well as the safety requirements for pollution‑free vegetables, thereby assessing the heavy metal levels in the vegetable sample.
II. The testing procedure for the heavy metal detector is as follows:
1. Rinse the sample to be tested with distilled or purified water (to remove surface soil and avoid interfering with the analysis), then dry it. Use a small knife or scissors to cut the sample into pieces approximately 1 cm in size, weigh out 1 g of the prepared sample, place it in a 20 mL plastic sampling tube, and add 10 mL of water.
2. Add 4 drops of Reagent A, use the stirring needle to press the sample below the liquid surface, cap the sampling tube, shake it up and down 10 times, let it stand for 1 minute, then shake it up and down another 10 times. Remove the fruit or vegetable sample and set it aside as the solution to be analyzed.
3. Transfer 1 mL of the sample solution into a blank sample tube.
Add 3 drops of Reagent B, cap the sample tube, and shake it up and down five times. Then add 2 drops of Reagent C and 2 drops of Reagent D, shake again five times, and allow the solution to develop at room temperature for 5 minutes.
By comparing the sample tube with the rapid test card for lead in fruits and vegetables, you can determine the reference concentration of lead in the sample.
III. Precautions for Using Heavy Metal Detectors:
When the sample contains metal ions such as iron, calcium, and magnesium, it may lead to false‑positive coloration in the solution. This method is suitable for the determination of free lead; for the determination of organic lead, conventional laboratory digestion procedures should be employed.
The above provides an overview of the detection principles, procedures, and precautions for heavy-metal analyzers. For more information, please continue browsing. Heavy Metal Detector Information Column If you’d like to learn more about the product, feel free to contact us online or by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.