[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
The working principle of a transformer oil chromatograph!
发布时间: 2022-11-04 11:05
In the work of power‑industry professionals, analyzing and testing the oil chromatogram of a transformer requires the use of a transformer oil chromatograph, also known as… Gas chromatograph This device is widely used in the power industry and is highly regarded by electrical professionals. So, what is the working principle of a transformer oil chromatograph?
Oil‑fluid chromatographic analysis is a separation‑and‑analysis technique for multi‑component mixtures. It primarily exploits the differences in boiling points, polarities, and adsorption coefficients of the components in the sample, enabling the separation of individual constituents within the chromatographic column and facilitating their qualitative and quantitative analysis.
Gas chromatography analyzers use a gas as the mobile phase (carrier gas). When a sample is introduced into the injector and vaporized, it is carried by the carrier gas into either a packed column or a capillary column. Due to differences in boiling points, polarities, and adsorption capacities among the components of the sample, these components are effectively separated within the column. Subsequently, a detector connected to the column—based on the physical properties of each component and its chemical structural characteristics—sequentially identifies and quantifies the individual constituents, generating corresponding detection signals. The resulting data are then transmitted via serial port or network to a chromatography workstation, which records the chromatograms of the various components in transformer oil and performs data management and analysis, ultimately producing a comprehensive analytical report for each component.
When the carrier gas composition and flow rate passing through the thermal‑conductivity cell remain stable, the cell’s temperature stays constant, and the current flowing through the tungsten filament’s thermal resistance remains unchanged, thereby maintaining the bridge circuit formed by the filament’s thermal resistance in a balanced state. When the gas of interest is carried into the cell by the carrier gas, a series of changes occur: the gas composition within the cell varies, the thermal conductivity of the gas mixture shifts, and both the thermal resistance and the temperature undergo alterations, ultimately resulting in the generation of a corresponding output signal.
Sensitivity is influenced by several factors in thermal conductivity detectors, including the resistance values of key components, the aperture of the gas‑sampling chamber in the cell, and the design of the thermal‑conductivity sensing element in the measurement circuit—each of which directly affects performance and helps establish optimal factory settings. User‑operational factors, such as current, bridge current, and high sensitivity, also play a role; however, these are constrained by stability, and the specific settings depend on the carrier gas used and the operating temperature of the thermal conductivity cell.
The above is an introduction to the working principle of the transformer oil chromatograph. If you would like to learn more, please continue browsing. Transformer Oil Chromatography Instrument Information Column !
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.