RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Limit values for hazardous substances and testing methods under RoHS!
发布时间: 2022-11-04 10:54
EU RoHS testing , I’m sure many companies have already dealt with this, so I won’t go into detail here. Today, I’ve summarized… ROHS testing Limits on hazardous substances and testing methods!
I. The latest EU‑mandated limits for hazardous substance content are as follows:
Cadmium 100 ppm;
Lead 1000 ppm;
Mercury 1000 ppm;
Hexavalent chromium 1000 ppm;
Polybrominated biphenyls 1000 ppm;
The polybrominated ether content of polybrominated diphenyl ethers is 1000 ppm.
Dioctyl phthalate 1000 ppm;
Dibutyl phthalate 1000 ppm;
Butyl benzyl phthalate 1000 ppm;
Diisobutyl phthalate 1000 ppm;
Note: PPM: For solids, the concentration unit is 1 ppm = 1 mg/kg. Homogeneous material: A material that cannot be further subdivided by physical means.
II. RoHS Testing Methods:
1. According to the relevant materials, RoHS can classify substances into two major categories: metals and non-metals. In accordance with European Community requirements, metallic materials must undergo testing for cadmium, lead, mercury, and other substances to produce a complete RoHS compliance report. Non-metallic materials are required to be tested for cadmium, lead, mercury, and polybrominated diphenyl ethers (the six restricted substances) to generate a comprehensive RoHS report.
2. Based on the testing method, analyses can be categorized into spectral scanning and chemical methods; spectral scanning yields results for specific wavelength ranges, while the chemical method enables determination of the exact concentration of each restricted substance. Depending on the product’s material composition, RoHS testing can be divided into raw-material testing, semi-finished-product testing, and finished‑product testing.
The above is an overview of the limit values for hazardous substances and the corresponding testing methods under RoHS. If you would like to learn more, please continue browsing our… ROHS Testing Information Column If you’d like to learn more about our instruments, feel free to contact us online or by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.