An introduction to the principles and characteristics of several analytical methods used in chromatography!
发布时间: 2022-11-03 10:45
Chromatograph The analytical methods include the elution method, the displacement method, and the counter‑current method. Below, we will discuss the principles and characteristics of each of these techniques.
I. Elution Method:
1. Operating principle:
The intermolecular forces between the analyte and the stationary phase are greater than those between the mobile phase and the stationary phase.
The mobile phase exhibits a much weaker adsorption or solubility affinity for the stationary phase than any of the sample components. Because each component differs in its adsorption or solubility behavior on the stationary phase, they elute from the column in a distinct sequence, thereby achieving separation.
2. Features:
This chromatographic column exhibits high separation efficiency and produces sharp, well-defined peaks, making it well suited for the separation of multi-component mixtures. The separated components can be readily eluted with the mobile phase, yielding substances of high purity. Consequently, elution is the most commonly employed method for sample recovery.
II. The Substitution Method:
1. Operating principle:
The interaction between the components and the stationary phase is weaker than that between the mobile phase and the stationary phase. By adding to the mobile phase a substance that exhibits stronger adsorption or solubility toward the stationary phase than any of the sample components—acting as a displacer—or by using this displacer directly as the mobile phase, the components are sequentially displaced from the stationary phase in accordance with their relative adsorption or solubility strengths. Alternatively, the component with the weakest adsorption–solubility affinity elutes first, while the component with the strongest affinity elutes last.
2. Features:
It is suitable for preparing pure substances and for concentrating and separating a specific component. However, after a single use, the chromatographic column becomes saturated with the sample or the eluent; therefore, before it can be reused, the column must either be replaced or the adsorbed substances must be removed.
III. The Head-On Method:
1. Operating principle:
Using the sample itself as the mobile phase, the sample is continuously passed through the chromatographic column. On the stationary phase, the component with the weakest adsorption or solubility elutes first as a pure substance, followed by a mixture of one component and a second, less strongly retained component, and so on.
2. Features:
When separating multicomponent mixtures, everything except the target component is impure; therefore, this method is suitable only for isolating high-purity components from mixtures containing trace impurities, but not for purifying the mixture itself.
The above provides an overview of the principles and characteristics of several analytical methods used in chromatography. If you would like to learn more, please continue browsing. Chromatography Instrument Information Section If you would like to learn more about the instrument, please contact us online or by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.