[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Comprehensive Governance Plan for Volatile Organic Compounds in Key Industries: Main Objectives, Control Approaches, and Requirements
分类: News Center
发布时间: 2019-07-05 16:02
II. Main Objectives
By 2020, a sound VOCs pollution prevention and control management system will be in place; significant progress will have been made in VOCs control in key regions and priority industries; the target of a 10% reduction in VOCs emissions set forth in the 13th Five-Year Plan will be achieved; greenhouse gas emissions will be jointly controlled; and continuous improvements in ambient air quality will be promoted.
III. Control Approach and Requirements
(1) Vigorously promote source‑level substitution. By adopting low‑VOC coatings such as waterborne, powder, high-solids, solvent-free, and radiation-curable formulations; low‑VOC inks including waterborne, radiation-curable, and plant-based types; low‑VOC adhesives like water-based, hot-melt, solvent-free, radiation-curable, modified, and biodegradable varieties; and low‑VOC, low-reactivity cleaning agents, we can replace solvent‑based paints, inks, adhesives, and cleaning agents, thereby reducing VOC emissions at the source. Industries such as industrial coating and packaging printing should intensify efforts to substitute at the source; the chemical industry should widely adopt raw and auxiliary materials with low (or zero) VOC content and low reactivity, and accelerate the green replacement of aromatic hydrocarbons and halogenated organic compounds. Enterprises should actively promote the use of low‑VOC wood coatings, vehicle coatings, machinery and equipment coatings, container coatings, and protective coatings for buildings and structures. In sectors where the technology is mature, the adoption of low‑VOC inks and adhesives should be advanced, with priority regions aiming to achieve near‑complete implementation by the end of 2020. Accelerating research, development, and production of low‑VOC paints, inks, adhesives, and related products is encouraged.
Strengthen policy guidance. Enterprises that use coatings, inks, adhesives, and other products compliant with national regulations on low-VOC content, whose emission concentrations consistently meet the standards and whose emission rates and performance metrics satisfy relevant requirements, may be exempted from installing end-of-pipe treatment facilities for the corresponding production processes. For processes using raw and auxiliary materials with a VOC content (by mass ratio) of less than 10%, measures to collect fugitive emissions are not required.
(2) Comprehensively strengthen the control of fugitive emissions. Focus on managing five categories of emission sources: the storage, transfer, and conveyance of VOC‑containing materials (including VOC‑containing raw and auxiliary materials, VOC‑containing products, VOC‑containing waste, and organic polymer materials), leaks from equipment and pipeline components, volatilization from open liquid surfaces, and process operations. By implementing measures such as enclosure of equipment and facilities, process optimization, and efficient collection of exhaust gases, fugitive VOC emissions will be reduced.
Strengthen the closed‑system management of equipment and facilities. VOC‑containing materials shall be stored in sealed containers or bags, high‑efficiency sealed storage tanks, enclosed warehouses, silos, and similar facilities. The transfer and conveyance of VOC‑containing materials shall be carried out using closed pipelines or sealed vessels, tank trucks, and other appropriate closed systems. For wastewater with high VOC content—where the VOC concentration measured 100 mm above the liquid surface exceeds 200 ppm (with a threshold of 100 ppm in key areas, expressed as carbon)—the collection, storage, and treatment processes must be conducted under covered, sealed conditions. During the production and use of VOC‑containing materials, effective collection measures shall be implemented, or operations shall be performed within enclosed spaces.
Promote the adoption of advanced production processes. By implementing fully enclosed, continuous, and automated production technologies, along with high-efficiency processes and equipment, uncontrolled emissions during manufacturing can be minimized. For the loading of volatile organic liquids, bottom-loading methods should be prioritized. In the petrochemical and chemical industries, priority should be given to using low- or zero-leakage pumps, compressors, filters, centrifuges, and drying equipment, while promoting online blending technologies for petroleum products and closed-loop circulating water cooling systems. In the industrial coating sector, compact coating processes should be vigorously advanced, with widespread adoption of roller coating, electrostatic spraying, high-pressure airless spraying, air-assisted airless spraying, and thermal spraying techniques. Enterprises are encouraged to replace manual spraying with automated and intelligent spraying equipment, thereby reducing reliance on air‑spraying technologies. In the packaging and printing industry, solvent-free lamination, extrusion lamination, and co-extrusion lamination technologies should be strongly promoted, and the use of water-based gravure printing, alcohol‑water gravure printing, radiation‑cured gravure printing, flexographic printing, and waterless offset printing is encouraged.
Increase the exhaust gas collection rate. Adhering to the principles of “collecting all that should be collected and segregating by quality,” design the exhaust gas collection system scientifically, converting fugitive emissions into controlled organized emissions. When using fully enclosed hoods or enclosed spaces, unless specific industry requirements dictate otherwise, maintain a slight negative pressure and appropriately size the ventilation rate in accordance with relevant standards. For localized hoods, at the farthest point from the hood opening where VOCs are emitted fugitively, the control air velocity shall be no less than 0.3 m/s; where industry-specific requirements exist, comply with the applicable regulations.
Strengthen leak control for equipment and pipeline components. Enterprises with equipment and pipeline components containing gaseous or liquid VOCs, where the number of sealing points is 2,000 or more, shall conduct LDAR activities in accordance with applicable requirements. Petrochemical enterprises shall comply with the emission standards specific to their industry.
(3) Promote the construction of appropriate and efficient pollution-control facilities. When enterprises build new pollution-control facilities or retrofit existing ones, they should select treatment technologies based on the concentration, composition, flow rate, temperature, humidity, pressure, and operating conditions of the exhaust gases, as well as other relevant factors. Enterprises are encouraged to adopt combined processes that integrate multiple technologies to enhance VOCs control efficiency. For low-concentration, high-volume exhaust streams, concentration techniques such as zeolite rotary adsorption, activated carbon adsorption, and air‑reduction‑and‑concentration are recommended to increase VOC concentrations prior to purification. For high-concentration exhaust, solvent recovery should be prioritized; where recovery is difficult, technologies such as thermal oxidation or catalytic oxidation are advisable. For the recovery of oil and gas (solvents), techniques like condensation–adsorption, adsorption–absorption, and membrane separation–adsorption are suitable. Low‑temperature plasma, photocatalysis, and photooxidation are primarily applicable to the control of malodors and unpleasant odors, while biological methods are best suited for treating low‑concentration VOC emissions and addressing malodors. Non‑water‑soluble VOCs must not be treated by spray absorption using water or aqueous solutions. When employing single‑use activated carbon adsorption, the carbon should be replaced regularly, and spent activated carbon must be regenerated or properly disposed of. Where feasible, industrial parks and industrial clusters should promote centralized spraying, centralized solvent recovery, and centralized activated carbon regeneration, thereby strengthening resource sharing and improving VOCs control efficiency.
Standardize engineering design. For systems employing adsorption treatment, compliance with the requirements of the “Technical Specification for Industrial Organic Waste Gas Treatment Using Adsorption” is required. For systems using catalytic combustion, compliance with the requirements of the “Technical Specification for Industrial Organic Waste Gas Treatment Using Catalytic Combustion” is required. For systems utilizing regenerative thermal oxidation or other treatment technologies, design shall be in accordance with the relevant technical specifications.
Implement dual controls on both emission concentrations and removal efficiencies for key emission sources. For exhaust gases collected from workshops or production facilities, where the initial VOCs emission rate is equal to or greater than 3 kg/hour, or in key areas equal to or greater than 2 kg/hour, stricter control measures shall be applied: in addition to ensuring that emission concentrations consistently meet regulatory standards, removal efficiency must also be controlled, with a minimum of 80%; except where the raw and auxiliary materials used comply with national regulations on low-VOC-content products, in cases where industry-specific emission standards exist, those standards shall prevail.
(4) Deepen the implementation of refined management and control. Local authorities should, in light of their specific needs for improving ambient air quality, conduct source apportionment analyses for O3 and PM2.5, and, taking into account industry-specific emission characteristics and the photochemical reactivity of VOCs, identify priority sectors and key pollutants for VOCs control in their respective regions. They should also address malodorous compounds and toxic and hazardous substances, and develop effective control measures to enhance the precision, specificity, and effectiveness of VOCs management. The nationally prioritized VOCs are listed in Annex 2.
Implement the “One Factory, One Plan” system. Local authorities should strengthen support and guidance for enterprises, particularly those with substantial local pollutant emissions, by convening experts to provide specialized technical assistance, rigorously vetting proposals, and helping companies develop practical, feasible pollution‑control plans. These plans should clearly define emission‑reduction requirements across the entire process—covering the substitution of raw and auxiliary materials, process improvements, control of fugitive emissions, exhaust‑gas collection, and construction of pollution‑control facilities—while estimating investment costs and quantifying emission‑reduction benefits, thereby providing technical services to enable effective comprehensive VOCs management. In key regions, local governments should organize enterprises with significant VOC emissions to prepare “One Factory, One Plan” schemes, aiming for near completion by the end of June 2020. Post‑implementation evaluations of control effectiveness should be conducted in a timely manner, and any subsidy policies introduced at the local level must be closely linked to actual emission‑reduction outcomes. Localities are encouraged to mandate mandatory clean‑production audits for priority industries.
Strengthen enterprise operations management. Enterprises should systematically identify and map the key stages and processes that generate VOC emissions, including start-up and shutdown procedures as well as inspection and maintenance activities, and develop detailed operating protocols, assigning specific responsibilities to designated personnel. Enhance internal performance‑assessment mechanisms. Intensify staff capacity‑building and technical exchanges. Establish management ledgers to document critical operational parameters of production processes and pollution‑control facilities (see Annex 3); ensure that online monitoring data can be accessed in real time, and retain relevant records for at least three years.
Source: Ministry of Ecology and Environment of the People’s Republic of China
Shenzhen Delptek Instrument Co., Ltd. is a high-tech enterprise specializing in the R&D, manufacturing, and sales of spectroscopic (XRF), chromatographic, and mass spectrometric products. The company has two wholly owned subsidiaries—Shenzhen Shengwangda Instrument Equipment Co., Ltd. and Shenzhen Dezewei Testing Technology Co., Ltd.—and holds controlling interests in Hong Kong Songsheng Electronics Co., Ltd. and the Longgang Wanda Industrial Park in Shenzhen. We boast an R&D team that combines X-ray fluorescence technology with expertise from German technical specialists, achieving outstanding results across diverse fields. Our spectroscopy, chromatography, and mass spectrometry instruments are already widely deployed in numerous applications. Website: http://www.delptek.cn/ Address: Building 8, Shangxiawei Entrepreneurship Industrial Park, Sha Jing Subdistrict, Bao’an District, Shenzhen Contact Information: Mobile: 18688929727 / 13751165856; Landline: 0755-66862188 Contacts: Ms. Liu, Mr. Yang E-mail: sell@delptek.cn
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.