News Center

News Center

What are the different types of chromatographs?

发布时间: 2022-10-31 10:59

Chromatograph By exploiting differences in the distribution, adsorption, ion exchange, size exclusion, or bioaffinity of components between the stationary phase and the mobile phase, the components undergo repeated interactions as they move relative to one another, thereby achieving separation. There are many classification schemes. Below is an introduction to the various types of chromatographs, for a brief overview.

I. According to the state of the mobile phase, they can be classified as:

1. Gas chromatograph: the mobile phase is a gas.

2. Liquid chromatograph: the mobile phase is a liquid.

II. According to the state of the stationary phase, they can be classified as:

1. Gas–liquid chromatograph: The mobile phase is a gas (known as the carrier gas), and the stationary phase is a liquid.

2. Gas-solid chromatograph: The mobile phase is a gas (known as the carrier gas), and the stationary phase is a solid adsorbent.

3. Liquid–liquid chromatograph: the mobile phase is a liquid (referred to as the eluent), and the stationary phase is a liquid.

4. Liquid-solid chromatograph: the mobile phase is a liquid (referred to as the eluent), and the stationary phase is a solid adsorbent.

III. According to the form of use of the stationary phase, they can be classified as:

1. Column chromatograph: The stationary phase is packed inside the column.

2. Thin-layer chromatography: The stationary phase is evenly coated onto a glass or plastic plate.

3. Paper chromatograph: Filter paper is used as the stationary phase or as a support for the stationary phase.

IV. According to the chromatographic column structure, they can be classified as:

1. Packed-column chromatograph: The chromatographic column is a packed column.

2. Capillary column chromatograph: The chromatographic column is a capillary column.

V. According to the separation mechanism, they can be classified as:

1. Partition chromatography: Separation is achieved based on the differential solubility of the components in the stationary liquid (stationary phase).

2. Adsorption chromatography: Separation is achieved by exploiting differences in the adsorptive affinity of the components on the adsorbent (stationary phase).

3. Ion-exchange chromatograph: Separation is achieved by exploiting the affinity of the components for the ion-exchange resin (stationary phase).

4. Gel chromatography: Separation is achieved by the selective permeation of molecules of different sizes through a porous stationary phase.

5. Bioaffinity chromatography: Separation is achieved by exploiting a specific affinity between biomolecules and the surface of the stationary phase.

The above is an introduction to the various types of chromatographs. If you would like to learn more, please continue browsing. Comprehensive Guide to Chromatography Instruments If you’d like to learn more about our products, please leave us a message online or contact us by phone!

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >