Operating procedures for using a heavy-metal rapid detector to test cadmium in rice!
发布时间: 2022-10-28 11:10
Below, we take... Portable heavy metal detector For example, let me introduce it to you. Heavy Metal Rapid Detector The procedure for detecting cadmium in rice—interested parties may wish to learn more!
Step 1: Sample Preparation:
Weigh 0.5 g of the sample (crushed or sieved) into a centrifuge tube, add 1 mL of extraction solvent, and dilute to 10 mL with distilled water. Under ultrasonic conditions at 200 W, perform ultrasonic extraction at 50 °C for 30 min. After extraction, filter or centrifuge for 5 min at 4,000 r/min, then transfer the supernatant to a clean centrifuge tube; this constitutes the sample solution to be analyzed. (Dilution factor A: 20-fold.)
Step 2: Electrode Preparation:
The working electrode must be polished and cleaned, and the three-electrode setup should be assembled correctly. The glassy carbon electrode serves as the working electrode and is inserted into the well marked with “W”; the silver–silver chloride electrode functions as the reference electrode and is placed in the well labeled “R”; and the platinum disk electrode acts as the counter electrode and is inserted into the well marked “C”.
Step 3: Coating:
1. Connect the instrument properly, then power it on and enter the heavy metal detection interface.
2. Preparation of the coating solution: Pipette 0.5 mL of the coating solution (B) and dilute to 10 mL with purified water.
3. Enter the electrode maintenance interface and select coating scheme B for on‑machine coating.
Note: The membrane contains a sublimable substance; before cleaning is complete, the electrode must not be exposed to air.
Step 4: Sample Testing:
Transfer 2 mL of the sample solution into an electrolytic cell, add 0.5 mL of electrolyte (for Cd/Pb/Cu/Zn), dilute to 10 mL with purified water, mix thoroughly, and proceed with instrument analysis.
The heavy-metal rapid detector, characterized by its extremely low cost and high sensitivity, can be used for on-site emergency monitoring—such as water‑environment contamination and heavy‑metal contamination in food—as well as for analyzing water quality, soil, cosmetics, food, and pharmaceuticals. The instrument employs anodic stripping voltammetry (ASV), a technique first developed in the 1920s and for which its inventor, Jaroslav Heyrovský, was awarded the Nobel Prize in Chemistry in 1959. Today, in Europe and North America, ASV has largely replaced traditional atomic absorption methods and is widely applied in pharmaceutical, biological, and environmental analyses; regulatory agencies such as the U.S. EPA have adopted it as a standard analytical method. In China, this method has also been incorporated into national standards for food safety and water‑quality testing, including GB 5009.12‑2010 “Determination of Lead in Food,” GB/T 5009.123‑2003 “Determination of Chromium in Food,” and GB/T 13896‑1992 “Determination of Lead in Water.”
The above are the operating steps for using a heavy-metal rapid detector to test cadmium in rice. If you would like to learn more, please continue browsing. Heavy Metal Detector Information Column If you’d like to learn more about our products, feel free to contact us online or by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.