Application of heavy metal detectors in cosmetic testing!
发布时间: 2022-10-25 10:56
With the rapid development of the fine chemical industry, cosmetics are increasingly endowed with a wider range of functions. Products that offer cleansing, skin‑care, and nourishing‑beauty benefits are gaining growing popularity. However, these cosmetics often contain lead, leading to excessive lead levels that can jeopardize users’ health. Due to its toxicity, lead and its compounds exert potent harmful effects on nearly all living organisms. Lead can enter the human body via the respiratory tract, the gastrointestinal tract, or the skin, where it accumulates and may trigger a variety of disorders affecting the nervous, metabolic, and endocrine systems, severely disrupting the body’s metabolism and normal physiological functions. Heavy metal detector It can rapidly and quantitatively determine the levels of heavy metals—lead, mercury, chromium, arsenic, and cadmium—in cosmetics. So today, let’s talk about the application of heavy metal detectors in cosmetic testing!
1. Principle of Heavy Metal Detector Operation
According to GB/T 5009.12-2010, heavy metal lead is extracted and reacted with a reagent to form a colored compound. The absorbance of this compound is measured at 550 nm using a detector; within a certain range, the absorbance is directly proportional to the lead content.
2. Test Subjects
Cosmetics
3. Heavy metal detector with its own reagents
1 mole per liter of nitric acid, 10 moles per liter of sodium hydroxide
4. Technical Specifications
Detection limit: 0.1 mg/kg
Linear range: 0–10 mg/kg
5. Operating Procedures for the Heavy Metal Detector
① Weigh 1.0 g (or 1.0 mL) of the sample into a 50-mL Erlenmeyer flask. For cosmetics containing organic solvents such as ethanol, first evaporate the organic solvent in a water bath or on a hot plate, then add 20 mL of 1 mol/L nitric acid and heat in a 100°C water bath for 1 hour. Remove the flask, allow it to cool, adjust the solution pH to neutral with 10 mol/L sodium hydroxide, and dilute to the 25-mL mark with water.
② Take a colorimetric cell, add 3 mL of the sample solution, and then add 2 drops of Heavy Metal Lead Test Solution A. Place the cell in the first channel and press “Control Measurement.”
③ Remove the colorimetric cell, add 2 drops of Heavy Metal Lead Test Solution B, mix thoroughly, place the cell in the measurement channel, and press “Sample Measurement.”
6. Execution Basics
According to the national standard “Hygiene Standard for Cosmetics,” the lead content in cosmetics shall not exceed 40 mg/kg.
7. Precautions for Heavy Metal Detectors
① After prolonged storage (two to three months), the reagent dosage for this project was increased from 2 drops to 6 drops.
② This method detects lead ions; the total lead content in real samples may exceed the measured result.
③ Heavy metal lead detection solution B should be stored sealed in a refrigerator at 0–4°C; shake well before use. Other reagents should be stored at room temperature, protected from light.
④ If the test result exceeds the assay’s detection range, it is recommended to dilute the sample and retest; the final result should be multiplied by the dilution factor.
⑤ The test solution used may cause varying degrees of skin irritation; please take appropriate precautions when handling it. If it comes into contact with the skin, wipe it off immediately and rinse thoroughly with plenty of water.
The above is an introduction to the application of heavy metal detectors in cosmetic testing. If you would like to learn more, please continue browsing. Heavy Metal Detector Information Column If you’d like to learn more about our products, please leave us a message or give us a call!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.