How much does a RoHS analysis instrument cost?
发布时间: 2022-10-25 10:22
RoHS Ten-Item Analytical Instrument It is widely used in industries such as semiconductors, new energy, 5G communications, hardware and building materials, aerospace, environmental protection, automotive, precious metal analysis, precision electronics, and electroplating. With numerous application requirements across these sectors, many manufacturers purchase RoHS‑compliant ten‑element analyzers. So, how much do these RoHS‑compliant ten‑element analyzers cost?
There are numerous manufacturers of RoHS‑compliant analytical instruments on the market, offering both imported and domestic brands. Prices vary significantly among these brands, making it difficult to provide a single, uniform quote. Typically, prices range from several hundred thousand yuan to over one million yuan; however, due to differences in product configurations and core technologies, price disparities can be substantial. We recommend contacting relevant RoHS 2.0 testing instrument manufacturers to assess your specific needs, as this will help you obtain more accurate pricing.
DePu Instruments’ RoHS‑compliant ten‑element analyzer is a compact, high‑precision spectroscopic instrument. It can be paired with an additional liquid chromatograph or a hyphenated mass spectrometry–chromatography system: one instrument analyzes elemental composition, while the other detects compounds. The advantages of this setup are as follows:
1. Trace sample analysis: The minimum measurable area is 0.03 mm² (measurement time can be as short as 0.01 s).
2. Zoom‑adjustment algorithm: Enables measurement of irregular samples at varying distances, with a zoom range of 0–30 mm.
3. Proprietary EFP algorithm: Li(3)-U(92) elemental coating, with multilayer, multi-element composition; even the same element can be measured with high precision across different layers.
4. Advanced spectroscopic technology: reduces interference from elements with similar energy levels and lowers the detection limit.
5. High-performance detector: SDD silicon drift detector with a window area of 25/50 mm²
6. Optical Path System: A microfocus X-ray tube equipped with a focusing and beam‑path switching mechanism.
7. Automatic switching among multiple collimators.
The above is RoHS Ten-Item Analytical Instrument Manufacturer An introduction to the pricing of ten analytical instruments for RoHS compliance. If you would like to learn more, please contact us. Despu Instruments specializes in… RoHS detector , RoHS 2.0 detector For production and R&D, if you’d like to learn more, please continue browsing our RoHS‑compliant analytical instrument information section. To inquire about our products, simply leave a message or contact us by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.