Optical Chamber Design for Direct-Reading Spectrometers
发布时间: 2019-06-17 15:58
Many people are familiar with direct-reading spectrometers and have even used them, yet few truly understand how they work—indeed, many know very little about them. This article provides a brief introduction to direct-reading spectrometers and highlights some key points to keep in mind when using them.
When analyzing certain types of metals—such as cast iron, stainless steel, low-alloy steel, Hastelloy, and Monel alloy—using an optical emission spectrometer, it is generally necessary to measure inorganic elements like carbon (C), phosphorus (P), sulfur (S), arsenic (As), and nitrogen (N). The optimal spectral lines for these elements all lie in the vacuum ultraviolet (VUV) region. However, oxygen, nitrogen, water vapor, and other constituents in ambient air strongly absorb UV‑region spectral lines, causing a sharp attenuation of the UV‑spectral intensity that the instrument can detect. This, in turn, compromises the accuracy and stability of the measurements for the target elements. Therefore, it is essential to evacuate the spectrometer’s optical chamber to eliminate atmospheric gases, thereby achieving more reliable and stable results for VUV‑region elemental analysis.
Currently, there are two methods for evacuating the optical chamber to enable the measurement of short-wavelength elements—more accurately referred to as UVU elements:
1. Vacuuming;
2. Fill with argon gas.
Vacuum pumping can create a pressure imbalance between the interior and exterior of the optical chamber, inducing deformation that alters the relative positioning of the grating and the CCD, thereby introducing measurement errors.
In addition, vacuum‑type optical systems consist of an optical chamber, a vacuum pump, solenoid valves, optical components, and electrical subsystems; consequently, spectrometers of this type tend to be relatively bulky. Moreover, some manufacturers, in an effort to reduce overall instrument costs, may equip their systems with low‑quality vacuum pumps and solenoid valves. This leads to a significantly higher failure rate over time, necessitating frequent maintenance; more seriously, it can result in oil or gas backflow into the optical chamber, damaging the diffraction grating. In mild cases, this may incur repair costs ranging from tens of thousands to hundreds of thousands of yuan, while in severe cases it can render the entire optical system irreparable.

Most manufacturers’ high-end direct-reading optical spectrometers typically employ a vacuum‑evacuated, single‑optical‑chamber design. This includes GNR’s S5, S7, and S9 models. For customers with specialized applications—such as analyzing a large number of elements, detecting ultra‑trace levels of elements like N, O, P, and B, or measuring Li and Na—the high‑end S9 model can be optionally equipped with a dual‑optical‑chamber hybrid detector system, which combines an air‑filled chamber with a vacuum‑evacuated chamber.
The second method of argon purging involves filling the optical chamber with an inert gas—typically argon—to displace the air, thereby creating an optimal analytical environment for detecting elements such as carbon, phosphorus, sulfur, arsenic, and nitrogen in the ultraviolet region. This approach eliminates the need for a mechanical pump and does not impose the same stringent vacuum‑tightness requirements as vacuum‑based systems. Moreover, the pressure differential between the optical chamber and the ambient atmosphere is negligible, so the chamber’s pressure‑resistance requirements are considerably lower. As a result, the instrument can be made more compact, greatly facilitating installation and relocation, while also reducing the failure rate associated with vacuum systems and lowering maintenance costs for users. Spectrometers employing this argon‑purging method typically use CCD or CID detectors, enabling full‑element (full‑spectrum) analysis and offering greater flexibility for future upgrades.
However, in CCD spectrometers, the technique of filling with argon gas also presents significant technical challenges. These include difficulties in gas‑path design and fluid‑flow testing, and manufacturers lacking sufficient experience find it hard to implement this approach. Consequently, most smaller manufacturers typically adopt a dual‑chamber design that combines a CCD with vacuum pumping.
Meanwhile, well-known spectrometer manufacturers typically leverage their technological and experiential advantages to adopt a more challenging yet superior CCD‑plus‑argon‑filled single‑chamber design. For example, GNR’s S1 and S3 direct‑reading spectrometers.
Source: Recommended by Yanzi’s Home
Shenzhen Delptek Instrument Co., Ltd. is a high-tech enterprise specializing in the research, development, manufacturing, and sales of spectroscopic (XRF), chromatographic, and mass spectrometric products. The company has two wholly owned subsidiaries—Shenzhen Shengwangda Instrument Equipment Co., Ltd. and Shenzhen Dezewei Testing Technology Co., Ltd.—and also holds controlling interests in Hong Kong Songsheng Electronics Co., Ltd. and the Longgang Wanda Industrial Park in Shenzhen. We boast an R&D team that combines X-ray fluorescence technology with expertise from German technical specialists, achieving outstanding results across various fields. Our spectroscopy, chromatography, and mass spectrometry instruments are already widely deployed in numerous applications. Website: http://www.delptek.cn/ Address: Building 8, Shangxiawei Entrepreneurship Industrial Park, Sha Jing Subdistrict, Bao’an District, Shenzhen Contact Information: Mobile: 18688929727 / 13751165856; Landline: 0755-66862188 Contacts: Ms. Liu, Mr. Yang E-mail: sell@delptek.cn
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.