[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Sources of Error in Liquid Chromatographs and Their Elimination!
发布时间: 2022-10-19 11:14
To improve the accuracy of the analytical results, Liquid chromatograph It is essential to account for the various sources of error that may arise during analysis and to implement effective measures to minimize them. So, what are the sources of error in liquid chromatography, and how can they be eliminated? Let’s take a look!
I. Sources of Error in the Sample Preparation Process
Sample preparation involves steps such as weighing, dissolution, and serial dilution. To minimize errors arising from operator‑related technical factors, sample handling should be performed with care. The duration of dilution for both the sample and the dilution reagents is a significant source of variability.
II. Sources of Error in Manual Injection
As the primary injection device, manual syringes remain the standard. Improper technique can lead to chromatographic issues, such as non‑linear calibration curves and poor reproducibility. Regular cleaning and maintenance of the injection valve help prevent contamination and blockages, eliminate interfering peaks, and enhance analytical accuracy. The injected sample volume should exceed three times the capacity of the quantitative loop to avoid partial sample overflow through the overflow port, which could introduce errors in quantitative analysis.
III. Sources of Systematic Errors in Instruments
1. Infusion pump
In analytical applications, inaccuracies in results caused by infusion pump malfunctions are very common. Contaminants such as dust and debris can enter the infusion tubing, leading to blockages; contamination of check valves can result in pressure instability; damage to sealing gaskets can cause system leaks; and failure of the plunger rod can prevent the mobile phase from flowing, thereby inducing pressure fluctuations. Ensuring the accuracy of analytical results and minimizing errors is critical for maintaining the stable and proper operation of the infusion pump.
2. The mobile phase causes changes in the composition of the mobile phase.
Errors arising from system configuration, proportional errors caused by malfunctions of online mixing pumps, and compositional changes upon storage. For example, the use of volatile solvents may lead to the loss of volatile components during vacuum degassing; the mobile phase can absorb carbon dioxide from the air, resulting in pH shifts. Variations in mobile-phase composition have a more pronounced impact on analytes with longer retention times. Even minor changes in the solvent composition can cause significant alterations in retention time.
3. Temperature change
Without a temperature‑controlled column oven, retention times are typically subject to variation due to temperature fluctuations. A column oven should be used, and the room temperature should be kept as stable as possible.
4. Chromatography column
After flushing the chromatographic column for 30 minutes, repeat the same sample every 10 to 20 minutes. If the retention times remain constant, this indicates that the system has reached equilibrium. It should be noted that a column may be equilibrated for one analyte but not for others. Therefore, formal analysis of the sample can only proceed once all components have achieved equilibrium.
IV. Conclusion
Enhance operational skills, work diligently and meticulously, carefully monitor controllable errors, and strive to minimize them as much as possible; this will improve the accuracy of the analytical results.
The above is an introduction to the sources of error in liquid chromatography and methods for their elimination. If you would like to learn more, please continue browsing. Liquid Chromatography Instrument Information Section If you’d like to learn more about our products, please feel free to leave a message or give us a call!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
