[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
It is not a hazardous substance subject to EU RoHS 2.0 restrictions!
发布时间: 2022-10-12 11:34
To protect human health and the environment, the European Union has established the RoHS mandatory certification for certain hazardous substances in electrical and electronic equipment. On June 4, 2015, the EU published the newly revised Directive (EU) 2015/863, known as RoHS 2.0. This is a mandatory standard enacted through EU legislation, officially titled the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” Some may wonder— isn’t it… EU RoHS 2.0 What harmful substances are subject to control? Let’s answer this question below!
I. Let’s first examine the implementation timeline for the EU’s RoHS 2.0:
1. Eight major categories of electrical and electronic equipment, effective January 2, 2013;
2. On July 22, 2014, medical devices (excluding active implantable medical devices) and monitoring equipment were brought under regulatory control;
3. On July 22, 2016, in vitro diagnostic medical devices were brought under regulatory control;
4. On July 22, 2017, industrial monitoring equipment was brought under regulatory control;
5. On January 23, 2019, all electronic and electrical equipment was brought under control.

RoHS 2.0 instrument (If you’re interested, please feel free to contact us by phone or leave us a message.)
II. Next, let us examine the 10 hazardous substances regulated under the EU RoHS 2.0:
1. Lead and its compounds
2. Mercury and its compounds
3. Cadmium and its compounds
4. Hexavalent chromium compounds,
5. Polybrominated biphenyls
6. Polybrominated diphenyl ethers
7. Di(2-ethylhexyl) phthalate
8. Butyl phthalate
9. Dibutyl phthalate
10. Diisobutyl phthalate (DIBP)
Note: DEHP, BBP, DBP, and DIBP were officially subject to control in 2019.
In summary, of the ten substances subject to RoHS 2.0 control as mentioned above, the remaining ones are not classified as hazardous substances under the EU RoHS 2.0 regulations—for example, mercury and other such substances. That concludes our overview of substances that are not subject to EU RoHS 2.0 restrictions. If you would like to learn more, please continue browsing. RoHS Industry Information Column !
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.