[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Advantages of using an ion chromatograph to analyze smog!
发布时间: 2022-10-11 10:43
As China’s economy continues to grow, people’s living standards are steadily improving. At the same time, an increasing number of environmental problems are coming to light. Among these, the most serious is smog, which refers to a combination of fog and haze. Fog is an aerosol system composed of numerous tiny water droplets or ice crystals suspended in the air near the ground, typically occurring during the autumn and winter seasons. Smog, on the other hand, consists of particulate matter—such as dust, sulfuric acid, nitric acid, and organic hydrocarbons—that further obscures the atmosphere. Smog poses a greater threat to human health, containing large amounts of fine particulates and more than 20 types of toxic substances harmful to the body, including acids, alkalis, salts, amines, phenols, dust, pollen, mites, influenza viruses, Mycobacterium tuberculosis, and Streptococcus pneumoniae. The concentration of these pollutants can be several times higher than that found in ordinary atmospheric water droplets. However, at present we can usually use Ion chromatograph To detect smog.
In the face of these extreme pollution events, we typically employ ion chromatography for analysis. Ion chromatography is a cutting-edge analytical technique capable of detecting ions and ionic compounds in environmental matrices such as water, air, and soil. In particular, in recent years, as relevant standards have continued to improve, ion chromatography is poised for significant advancement. Using an ion chromatograph to analyze haze has the following advantages:
1. Fast and convenient: Typically, IC analysis of a single sample takes only about 10 minutes on average. For several common anions and cations, the average analysis time can be less than 8 minutes.
2. Good selectivity: By selecting an appropriate separation method, column, and detection technique, the IC method can achieve selective analysis of both inorganic and organic cations and anions.
3. Excellent column stability: The high pH stability of IC column packing permits the use of strong acids or strong bases as eluents, thereby broadening the range of applications.
4. Simultaneous analysis of multiple ions: It is very easy to achieve the simultaneous separation of more than ten ions within approximately 20 minutes. In a single injection, ions with varying concentrations can also be accurately quantified.
5. High sensitivity: Ion chromatography can analyze concentrations ranging from a few micrograms per liter (1–10 µg/L) to several hundred milligrams per liter, using direct injection (25 µL) and conductivity detection; the detection limits for common anions are less than 10 µg/L.
As the functionality of ion chromatographs continues to improve, they are finding applications in an ever-growing number of industries. It is foreseeable that ion chromatography will enjoy even greater market prospects in the years to come. If you would like to learn more, please continue browsing our… Chromatography Instrument Knowledge Column !
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
