[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
How can a smartphone avoid being detected by a metal detector?
发布时间: 2022-09-30 13:59
Metal detector It emits a magnetic field, inducing eddy currents in metal, and these eddy currents, in turn, generate their own magnetic field. When the detector picks up this signal, it triggers an alarm. Moreover, a mobile phone’s radio signal is also a form of magnetic field, which can similarly set off the detector. So how can a mobile phone avoid being detected by a metal detector? Let’s discuss this issue.
1. All you need to do is place your phone in a blind spot where the metal detector can’t scan it, or wrap it in materials made of special substances. As everyone knows, a metal detector is designed to detect metal, and phones invariably contain metallic components. As long as your phone remains within the detector’s scanning range, it will inevitably trigger an alarm.
2. You can place it inside your shoes. It generally won’t come into contact with the exterior of your footwear, and you can simply wrap it in several layers of aluminum foil before bringing it in. The metal detector employs a modular differential transformer sensor and incorporates cutting-edge metal detection technology—digital phase‑shift and related detection techniques—in its circuit design. These features ensure stable, reliable performance, high detection sensitivity, strong material‑suppression capabilities, and robust anti‑interference properties. This product is primarily used in industries such as thermal power generation, cement, building materials, papermaking, mining, food processing, and chemical manufacturing to detect various metallic contaminants mixed within raw materials. It operates by detecting the induced signals generated when metals enter the sensor’s electromagnetic field; these signals are amplified and processed to activate actuators, thereby identifying harmful metallic impurities.
3. You need to turn off your phone (to prevent the magnetic field it generates from being detected).
4. Coat your phone with a layer of electromagnetic-wave-absorbing material (to absorb the magnetic field emitted by metal detectors), but this will render your phone unable to communicate.
5. Place your smartphone inside a container, then wear it on your body. The container must be capable of absorbing electromagnetic waves. Of course, don’t expect this to work for ordinary civilians. High‑end technologies such as stealth aircraft and radar‑evading planes all rely on materials of this kind.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.