Use and Principle of Halogen Moisture Analyzers

分类: News Center

发布时间: 2019-05-14 15:49

The halogen rapid moisture analyzer is an ideal instrument for moisture determination in both production and research, and it is now widely employed across various industries for moisture monitoring, as well as in academic and research settings.

Such as pharmaceuticals, plastics, chemicals, and food products (including surimi, dehydrated vegetables, processed meat and seafood, noodles, flour, biscuits, mooncakes, etc.), as well as grains, animal feed, seeds, rapeseed, tobacco, tea, and industries like textiles, agriculture and forestry, papermaking, rubber, and powder processing.

Precautions for using a halogen moisture analyzer:

To fully leverage the functionality of the moisture analyzer and provide convenience to your enterprise, please be sure to follow the precautions below.

1. During moisture determination, ensure the workbench remains stable and avoid any drafts or air currents in front of the moisture analyzer.

2. When determining the sample, it is preferable to spread it evenly across the bottom of the weighing dish (the layer should be as thin as possible to facilitate complete evaporation of moisture).

3. After placing the sample, close the heating unit and wait until the weight reading stabilizes before pressing the test button to determine the moisture content.

4. The sample weight should be kept as consistent as possible for each measurement, and the initial temperature should be maintained at the same level for every test.

5. During moisture meter measurements, do not use or make phone calls in the vicinity of the instrument.

6. During moisture determination, do not touch the heating device with your hands, and strictly prohibit striking or directly vibrating the work surface.

7. As the instrument’s weighing system comprises precision components, its load-transmission parts are highly susceptible to damage from excessive weight or impact. Therefore, a support bracket must be used whenever placing or removing sample dishes; direct handling of the dishes with bare hands is strictly prohibited.

8. After the measurement is completed, remove the sample dish using the holder to avoid burns. Once the holder is securely placed in the instrument, ensure it does not come into contact with the load-bearing support or the sample dish.

9. After completing the measurement, allow the sample dish to cool completely, or wait until the instrument’s current temperature drops below 30°C, before testing the next sample.

10. Before each measurement, the instrument’s weight display must be set to zero. If the display does not read zero, press the zero‑set button to reset it.

11. After the measurement is completed, allow the sample dish to cool completely before cleaning it.

Principle:

The rapid moisture analyzer is based on the principle of thermal decomposition. Although the industry uses various names, they all refer to the same product—also known as a halogen moisture meter, halogen moisture analyzer, or halogen moisture detector. However, the quality and performance of these instruments can vary significantly among different manufacturers.

Source: Guolian Resources Network

Shenzhen Delptek Instrument Co., Ltd. is a high-tech enterprise specializing in the research, development, manufacturing, and sales of spectroscopic (XRF), chromatographic, and mass spectrometric products. The company has two wholly owned subsidiaries—Shenzhen Shengwangda Instrument Equipment Co., Ltd. and Shenzhen Dezewei Testing Technology Co., Ltd.—and holds controlling interests in Hong Kong Songsheng Electronics Co., Ltd. and the Longgang Wanda Industrial Park in Shenzhen. We boast an R&D team that combines X-ray fluorescence technology with expertise from German technical specialists, achieving outstanding results across diverse fields. Our spectroscopy, chromatography, and mass spectrometry instruments are already widely deployed in various applications. Website: http://www.delptek.cn/ Address: Building 8, Shangxiawei Entrepreneurship Industrial Park, Sha Jing Subdistrict, Bao’an District, Shenzhen Contact Information: Mobile: 18688929727 / 13751165856; Landline: 0755-66862188 Contacts: Ms. Liu, Mr. Yang E-mail: sell@delptek.cn

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >