What are the commonly used carrier gases for gas chromatographs?
发布时间: 2022-09-21 10:50
As Gas chromatograph The carrier gas should exhibit excellent chemical stability, high purity, and affordability, while being compatible with the detector in use. So, what are the commonly used carrier gases in gas chromatography? Let’s take a look!
1. Hydrogen: Due to its low molecular weight, large molecular radius, high thermal conductivity, and low viscosity, hydrogen is commonly used as a carrier gas. It is also an essential gas in FID detectors. Currently, in addition to high-pressure hydrogen cylinders, hydrogen can also be produced via water electrolysis. Hydrogen is highly flammable and explosive; therefore, strict safety precautions must be observed during its use.
2. Nitrogen: Due to its low diffusion coefficient and high column efficiency, nitrogen is commonly used as the carrier gas in detectors other than the TCD. The reason it is less frequently employed in the TCD is primarily because nitrogen has a relatively low thermal conductivity, resulting in lower sensitivity. However, when analyzing hydrogen (H₂), nitrogen must be used as the carrier gas; otherwise, the TCD cannot adequately address H₂ detection.
3. Helium: In terms of its performance as a chromatographic carrier gas, helium is comparable to hydrogen and offers superior safety. However, due to its higher cost, it is used less frequently.
4. Before selecting a carrier gas, consider the type of detector being used. When employing a thermal conductivity detector, using hydrogen or helium as the carrier gas can enhance sensitivity; moreover, hydrogen as the carrier gas can extend the service life of the tungsten filament in the thermal sensing element. For a hydrogen flame ionization detector, nitrogen or hydrogen is recommended as the carrier gas. Electron capture detectors typically use high-purity nitrogen, while nitrogen and hydrogen are commonly employed in flame detectors.
In general, the commonly used carrier gases for gas chromatographs include hydrogen, nitrogen, argon, helium, carbon dioxide, and others. If you would like to learn more about… Gas Chromatography Instrument Information Yes, you can continue browsing our website or contact us online!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.