[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
What is the detection principle of a halogen analyzer?
发布时间: 2022-09-13 11:08
Halogen analyzer It is a new type of rapid moisture‑testing instrument. Its annular halogen heater ensures uniform heating of the sample during high‑temperature testing, minimizing surface damage and enabling rapid drying. Throughout the drying process, the halogen analyzer continuously measures and instantly displays the percentage of moisture loss. Once drying is complete, the final moisture content reading is locked and displayed. Compared with the international oven‑drying method, this instrument delivers highly consistent and comparable results, with testing efficiency far exceeding that of the oven method. So, what is the underlying principle of the halogen analyzer? Let’s take a look!
We all know that the halogen elements include fluorine (F), chlorine (Cl), bromine (Br), iodine (I), and astatine (At). Among these, astatine is a radioactive element, while the term “halogens” typically refers to fluorine, chlorine, bromine, and iodine. The first four of these elements are found in products—in particular, in polymeric materials—in the form of organic compounds. The hazards associated with halogens are primarily manifested in the following ways:
1. Organic halogen compounds are inherently toxic and, when accumulated in the human body, can cause cancer.
2. Halogenated compounds exhibit very low biodegradation rates, leading to their accumulation in ecosystems. Moreover, certain volatile organic halogens exert significant ozone-depleting effects, posing serious risks to the environment and human health.
3. Halogenated plastics release hydrogen halides (such as HCl, HBr, etc.) which, upon exposure to high temperatures or atmospheric water vapor, form acidic fumes.
4. When halogenated plastics undergo incomplete combustion, they produce dioxins, which are highly bioaccumulative and persistent carcinogens.
5. When halogenated plastics burn, they produce large amounts of smoke and toxic, corrosive gases, which impede firefighting and evacuation efforts and corrode instruments and equipment.
Therefore, once the hazards of halogen elements are identified, a halogen analyzer is required to detect them and enable appropriate remediation. Let’s take a look at the operating principle of such an analyzer: typically, sample analysis can be completed in just a few minutes. The instrument is easy to operate and delivers highly accurate results. Its display uses red LED digits, ensuring clear and legible readings. It can show moisture content, initial and final values, measurement time, as well as initial and final temperature readings, among other data. Additionally, it features connectivity options for both computers and printers. Halogen analyzers are widely applicable across industries that require rapid moisture determination, including pharmaceuticals, plastics, chemicals, and food processing—such as surimi, dehydrated vegetables, meat and seafood products, noodles, flour, biscuits, mooncakes, and more—as well as in production and laboratory settings. They are also used in grain, feed, seed, rapeseed, tobacco, tea, textile, agriculture and forestry, papermaking, rubber, and other sectors.
The above is an introduction to the detection principle of halogen analyzers. If you would like to learn more, Halogen Analyzer Information Yes, you can continue to visit our website or contact us by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.