What are the chromatographic peak parameters analyzed by a chromatograph?
发布时间: 2022-09-13 10:46
Chromatograph It is a common analytical instrument, and the chromatographic peak is a product of the chromatograph. Now, let’s discuss the key parameters of chromatographic peaks in chromatographic analysis—those who are interested can learn more!
1. Chromatogram:
It refers to the curve depicting the variation of the detector’s electrical signal intensity with time in chromatographic analysis, also known as the chromatographic elution profile.
II. Baseline:
Refers to the response signal of the detector when only the mobile phase passes through it, after the chromatographic operating conditions have stabilized.
III. Baseline Noise:
It refers to a signal in which the baseline exhibits short-term fluctuations solely due to the detector itself and other operational conditions, even in the absence of sample entering the detector.
IV. Baseline Drift:
It refers to the slow, unidirectional change of the baseline over time.
5. Chromatographic Peaks:
Refers to the prominent peak on a chromatographic elution curve.
VI. Peak Height:
Refers to the vertical distance between the chromatographic peak and the baseline.

7. Peak Width:
Peak width is a parameter used to quantify the breadth of a chromatographic peak.
1. Peak width Wb:
It refers to the distance between the two points where the tangents at the inflection points on either side of a chromatographic peak intersect the baseline.
Wb=4σ
2. The half-height width is 0.5h:
The peak width at half the height of the chromatographic peak.
W0.5h = 2.354σ
3. Standard deviation σ:
Normal peak: σ is 0.607 times the peak height and half the peak width.
8. Symmetry factor fs:
fs = W0.05h/(2A)=(A + B)/(2A)
Where: W0.05h denotes the peak width at 0.05 times the peak height.
a and b are, respectively, the distances between the leading edge and the trailing edge of the chromatographic peak and the vertical line drawn from the peak apex to the baseline, each equal to 0.05 times the peak height.
1. Symmetric peak: fs = 0.95~1.05
2. Forward Extension Peak: FS < 0.95
3. Tail peak: FS > 1.05
9. Peak Area:
Refers to the enclosed area between the chromatographic elution curve and the baseline.
X. Pre-Extension Peak:
It refers to an asymmetric chromatographic peak that is broad at the front and steep at the back.
11. Tail Peak:
Refers to an asymmetric chromatographic peak that is steep at the front and gradual at the back.
XII. Abnormal Peak:
Refers to a chromatographic peak with an asymmetric shape.
Thirteen, Anti-Peak:
A chromatographic peak whose shape is opposite to that of a typical peak, also referred to as an inverted peak or a negative peak.
XIV. Fake Peak:
It refers to chromatographic peaks arising from causes other than the normal elution of the analyte, also known as ghost peaks.
In summary, the chromatographic peak parameters analyzed by a chromatograph include the chromatogram, baseline, baseline noise, baseline drift, chromatographic peaks, peak height, peak width, asymmetry factor, peak area, fronting peaks, tailing peaks, distorted peaks, reverse peaks, and ghost peaks. The above constitutes an introduction to the chromatographic peak parameters in chromatographic analysis; if you would like to learn more about… Chromatograph Information Yes, you may continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.