Precautions for Disassembling an ROHS Fluorescence Analyzer!
发布时间: 2022-09-13 10:19
RoHS fluorescence analyzer It is an instrument used for RoHS testing and is commonly employed in routine production. Below are some important considerations when disassembling a RoHS fluorescence analyzer—those interested may wish to take a look!
1. The objective of disassembly is to obtain homogeneous materials that constitute electronic and electrical products through appropriate disassembly methods. Appropriate splitting procedures should be employed to ensure that the resulting homogeneous materials do not lead to misinterpretations in subsequent testing due to improper splitting.
2. Multiple modules, components, or parts manufactured by the same producer and having identical functions and specifications (parameters) may be grouped into a single category, with representative samples selected for disassembly. Different components produced from the same materials (including base materials and additives) may be treated as a single test unit.
3. Materials of different colors shall be assigned to separate test units.
4. Items or materials listed as exempt under applicable laws and regulations shall be clearly marked at the time of dismantling.
5. When the object to be split is difficult to further divide and its weight is ≤10 mg, no further splitting is required; it will be submitted directly as a heterogeneous test sample.
6. When the material to be split is difficult to further subdivide, with a particle size of less than 2 mm or a volume of ≤ 4 mm³, it need not be split; instead, a whole sample may be prepared and submitted directly as a non-homogeneous testing unit.
7. The thickness of metal specimens shall be at least 3 mm. If a single specimen is insufficient in thickness, several specimens may be stacked to achieve the required thickness. Other alloys must have a minimum thickness of 1 mm.
8. The flat portion of the sample shall be 5 × 5 mm; if necessary, the sample shall undergo preliminary treatment (e.g., flattening).
9. Ink or other liquids shall be measured using a sample cup with a depth of 15 mm; fine particles must also be compacted in the sample cup to fill approximately two-thirds of its volume. The surface‑treatment layer should, whenever possible, be separated from the bulk material (e.g., coating). For cases where separation is not feasible (e.g., coatings), preliminary screening of the surface‑treatment layer may be performed (e.g., using an ROHS spectrometer). If the screening passes, no further disassembly is required; if it fails, mechanical or non‑mechanical methods may be employed for separation (e.g., dissolution extraction using a solvent that dissolves the surface‑treatment layer but not the base material).
10. Provided that the test results remain valid, if the split samples fail to meet the testing requirements, they may be appropriately grouped and combined into a single preparation for direct submission for testing.
The above is an overview of the precautions to take when disassembling an ROHS fluorescence analyzer. If you would like to learn more about… ROHS fluorescence analyzer information Yes, you can continue browsing our website or contact us!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.