[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
What are the differences between China’s RoHS and the EU’s RoHS?
发布时间: 2022-09-08 10:38
Something known as “China RoHS” and which has been in effect for many years. EU RoHS What are the differences? We will analyze the distinctions between China’s RoHS and the EU’s RoHS from the following perspectives.
I. Different scopes of control
EU RoHS: Regulates electrical and electronic products operating at 1,500 volts DC and below 1,000 volts AC, except for exempted products.
China RoHS: refrigerators, air conditioners, washing machines, electric water heaters, printers, copiers, fax machines, televisions, monitors, microcomputers, mobile communication handsets, and standalone telephones. (The first batch of 12 categories of electronic and electrical products was included in the regulatory catalog on March 15, 2019.) China adopts an exhaustive approach, as stipulated in the “Catalogue for the Administration of Restrictions on the Use of Hazardous Substances in Electrical and Electronic Products.”
II. Different Controlled Substances
The EU RoHS directive lists 10 restricted substances: lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB), polybrominated diphenyl ethers (PBDE), di(2-ethylhexyl) phthalate (DEHP), butyl benzyl phthalate (BBP), dibutyl phthalate (DBP), and diisobutyl phthalate (DIBP). This is RoHS 2.0!
China’s RoHS regulation covers only six substances: lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (CrVI), polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE). This corresponds to RoHS 1.0.
III. Different Regulatory Systems for the Production Process
EU RoHS: The regulatory approach primarily relies on random inspections in the distribution sector.
China RoHS: While the distribution sector is subject to regulatory oversight, stricter supervisory measures have also been implemented throughout the production process (under the purview of the Municipal Administration for Market Regulation and the Ministry of Industry and Information Technology). Under China RoHS, manufacturers of products listed in the regulatory catalog are required to opt for either national voluntary certification or self‑declaration and to submit the relevant information to a unified platform.
IV. Different Certifications
EU RoHS: The EU RoHS does not impose mandatory certification requirements; however, the EU has established the IECQ‑QC080000 standard for managing hazardous substances in manufacturing processes. Companies may voluntarily seek certification under this system, which is based on the ISO 9001 framework.
China RoHS: You must choose either “National Promotion Voluntary Certification” or “Self‑Declaration.” National Promotion Voluntary Certification offers four certification modes.
V. Self-Declaration
EU RoHS: No mandatory requirements.
China RoHS: You must choose between “Nationally Promoted Voluntary Certification” and “Self-Declaration.”
VI. Requirements for Appraisal
EU RoHS: No labeling requirements.
China’s RoHS: It includes labeling requirements, with the Measures for the Administration of the Use of Green Product Labels set to take effect on June 1, 2019.
VII. Requirements for Testing Institutions
EU RoHS: Third-party test reports are provided upon request. Of course, the testing laboratory is an ISO/IEC 17025‑accredited lab and is recognized by CNAS in China.
China RoHS: Nationally Promoted Voluntary Certification: Testing of certification samples shall be conducted by inspection and testing institutions contracted by the certification body, which must meet the relevant competence and qualification requirements. The test reports submitted in self-declarations may originate from the manufacturer’s or production enterprise’s own laboratories that possess the requisite technical capabilities, from qualified third-party inspection and testing institutions, or from suppliers who hold complete component‑level documentation; in such cases, the compliance reports are based on the determination of hazardous substances in the raw materials.
VIII. Testing Methods and Splitting Rules
EU RoHS: IEC 62321.
China RoHS: Limitation and disassembly requirements shall be in accordance with GB/T 26572, and the testing methods shall comply with the GB/T 26125 standard.
IX. Public Notice Requirements
EU RoHS: There are no mandatory requirements; the focus is primarily on sharing relevant information throughout the supply chain.
China RoHS: Whether through voluntary certification or self‑declaration, electronic and electrical products must be reported to the public service platform for the restriction of hazardous substances, enabling data sharing.
The above is an overview of the differences between China’s RoHS and the EU’s RoHS. If you would like to learn more about… RoHS information Yes, you may continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.
