The structure of a full-spectrum direct-reading spectrometer!
发布时间: 2022-09-06 10:28
Full-spectrum direct-reading spectrometer As a type of analytical instrument, what is the structure of an optical emission spectrometer with full‑spectrum direct reading? Let’s take a look!
I. Excitation System:
1. High-energy pre‑ignition, low‑pressure spark excitation source with a high-purity argon excitation atmosphere: By employing high‑energy pre‑ignition, the influence of sample matrix on atomization performance is significantly reduced.
2. High-voltage spark excitation source, high-purity argon excitation atmosphere: the measured light intensity is unstable.
3. Low‑pressure spark excitation source with a high‑purity argon atmosphere: The spectral intensity remains stable for the same sample, but it is unable to mitigate the effects of sample matrix on atomization.
4. DC arc‑excited light source and a high‑purity argon excitation atmosphere: These conditions significantly enhance the spectral resolution and detection limits for trace elements in the sample.
5. High-purity argon excitation atmosphere in the CNC excitation source: Based on the spectral characteristics of each element in the sample, the excitation process is divided into several flexibly adjustable time segments, with each segment delivering excitation only to a subset of elements that share similar conditions, thereby collecting signals exclusively from those elements. The excitation states of each element are then categorized and analyzed according to experimental findings.
II. Optical System:
1. Paschen–Runge optical system (fixed optical path, concave grating, and an exit slit array mounted on the Rowland circle): This optical system features a stable structure but has a large footprint.
2. Trapezoidal cross‑dispersion optical system (employing a dual‑monochromator cross‑dispersion configuration to achieve high‑level, high resolution, and utilizing secondary dispersion to address spectral order overlap): compact in size, with high resolution, and typically coupled to a solid‑state imaging system for data acquisition.
III. Measurement and Control System:
1. Measurement System:
(1) Photomultiplier tubes, integrating circuits, and analog-to-digital conversion circuits: These are typically used as spectral detectors in Paschen–Runge or C–T optical systems. The circuitry following the photomultiplier tube can only measure the intensity of a single spectral line.
(2) CCD/CID detector DSP: Typically used as a collector in stepped cross-dispersion optical systems, it offers slightly lower sensitivity than a photomultiplier tube but can be employed for full-spectrum acquisition.
2. Control:
(1) Excitation control, optical path control, and acquisition control with multi-layer optoelectronic isolation
(2) A highly interference-resistant communication protocol is employed to achieve efficient data feedback and control.
IV. Computer Software and Data Processing Systems:
1. Internal Standard Method
2. Generate curves using standard materials.
3. Data screening using PDA technology.
4. Perform background and ternary interference suppression on the measurement data acquired via the software channel.
5. Restore instrument drift by using control samples.
In summary, an all‑element direct‑reading optical emission spectrometer is an instrument that analyzes samples by measuring the intensity of the spectral lines characteristic of each element. At present, both domestically and internationally, photoelectric direct‑reading optical emission spectrometers can be broadly categorized into four functional modules, namely:
A. Excitation System: Its function is to atomize solid samples thoroughly by various means, thereby generating the emission spectra of the constituent elements.
B. Optical System: Processes the complex optical signals generated by the excitation system (classification, separation, screening, and capture).
C. Measurement and Control System: Measures the intensities of characteristic spectral lines corresponding to each element and, by various means, converts these optical intensity signals into digital electrical signals that can be recognized by a computer, thereby ensuring the proper operation of the entire instrument.
D. Software-based data processing system in the computer: performs various arithmetic operations on the light intensity data received from each channel, yielding stable and accurate sample concentrations.
The above is an introduction to the structure of the full-spectrum direct-reading spectrometer. If you have… Full-spectrum direct-reading spectrometer information If you’d like to learn more, feel free to continue browsing our website or contact us!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.