[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Which is better: a benchtop RoHS analyzer or a handheld RoHS analyzer?
发布时间: 2022-09-05 09:47
Speaking of ROHS environmental testing instrument , let’s take a look at what an ROHS environmental testing instrument is. The ROHS environmental testing instrument referred to here is a device that utilizes X-ray fluorescence spectrometer An instrument used to test the content of six hazardous substances under RoHS. It boasts the advantages of an X-ray fluorescence spectrometer, offering rapid detection. It is broadly categorized into handheld and benchtop models; therefore… Desktop RoHS detector and Handheld RoHS detector Which one is better? Let’s take a quick look!
1. The desktop ROHS environmental tester must be used in conjunction with a computer. Desktop ROHS analyzers are the most widely used instruments on the market. Their dimensions typically measure around 550×400×350 mm, and their weight generally does not exceed 60 kg.
II. Handheld ROHS Analyzer, Typical dimensions are approximately 250 × 90 × 330 mm, with a weight not exceeding 2 kg. Compared to benchtop instruments, handheld devices are used far less frequently in ROHS testing.
III. In fact, compared with handheld ROHS detectors, benchtop instruments offer numerous advantages. We can list some of them.
1. Benchtop instruments used for RoHS testing offer advantages over handheld devices in both design and functionality, with superior measurement accuracy. This is because benchtop instruments provide significantly better heat dissipation than handheld units, making them better suited for continuous testing.
2. Radiation safety protection is significantly improved. Typically, benchtop instruments incorporate multiple layers of shielding, providing multi‑layered safeguards against radiation. The instrument’s outer casing is made of lead, and the metal enclosure effectively attenuates any leakage of radiation.
3. The instrument is equipped with a high-voltage interlock. When the interlock is closed, the radiation source cannot be activated.
4. The instrument’s software also includes a start button. If it is not activated, the radiation device will not turn on.
5. The instrument is equipped with a built-in radiation‑shielding lock. When the instrument is powered on, radiation is automatically disabled.
In summary, benchtop instruments are more accurate and offer superior radiation safety protection than handheld devices.
4. However, handheld instruments also offer a distinct advantage: when testing large samples that cannot fit into the sample chamber of a benchtop instrument, using a benchtop device would require cutting the sample, which could damage it. In contrast, handheld instruments avoid this issue and allow direct measurement.
5. In addition, some customers purchase instruments primarily for environmental compliance testing of raw materials. Handheld instruments, with their compact size, can be easily carried on-site for testing and presented directly to suppliers for immediate analysis.
So, in the end, the question remains: is a benchtop instrument better, or a handheld one? Each has its own advantages. When choosing an instrument, you should prioritize your specific application needs. If the sample size is small, there’s no need to remove it for testing. From a safety standpoint, it’s still best to opt for a benchtop instrument. After all, the ultimate goal of acquiring such equipment is to accurately measure the levels of harmful substances in samples, thereby achieving environmental protection and ensuring safety.
The above is an overview of the differences between desktop and handheld RoHS analyzers. If you have any instrument‑related needs, please feel free to contact us by phone or leave us a message online!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.