[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Technical and calibration requirements for using an ROHS detector!
发布时间: 2022-09-02 10:15
As modern products become increasingly abundant, people are paying growing attention to their own safety. Nowadays, many customers choose to use… ROHS detector Conduct testing. Below, we will outline the technical and calibration requirements for using an ROHS detector.
When using an ROHS detector, first ensure that the instrument is clean, well-organized, and fully equipped, and correctly identify all markings on the device, including the model number, instructions on the control panel, the factory‑issued serial number, and the instrument’s readings. Verify that all components are functioning properly, calibrate the instrument’s measurement range, and use the device in accordance with the specifications and technical requirements outlined in the user manual.
I. Main Objectives of Calibration
The calibration targets of the ROHS detector include ABS materials compliant with national standards, which contain mercury, bromine, lead, chromium, and cadmium.
II. Calibration Equipment
A standard material set for the analysis of lead, mercury, cadmium, chromium, and bromine in ABS, equipped with an ROHS detector.
III. Environmental Requirements
When using an ROHS detector, first check for vibration sources and AC interference in the vicinity of the instrument. Next, determine whether corrosive gases (such as acids, alkalis, or strong air currents) are present in the surrounding environment, and verify the connections between the instrument and its power supply. Ensure that both the instrument and the power source are functioning properly. Finally, maintain the ambient temperature within the range of 15°C to 30°C, as specified in the instrument’s user manual.
IV. Installation Requirements
During the installation of an ROHS detector, it must be carried out strictly in accordance with the specified requirements.
1. Secure the instrument firmly to the workbench.
2. Verify that the instrument is properly connected to the power supply.
3. Each plug-in component on the instrument can be securely configured and matched.
V. Usage Requirements
1. The instrument and the workbench must be kept clean. If there is dust or debris, wipe it off with an alcohol‑soaked cotton swab or a dry, soft cloth; do not use alkaline or acidic cleaning agents.
2. During testing, prevent dust particles from falling onto the workbench to avoid contamination and measurement errors. Keep the test window clean, and do not touch it with hard objects to prevent damage.
3. Handle with care to avoid damaging the window film and preventing damage caused by dropped samples.
4. If the instrument is not to be used for a short period, do not turn off the power; otherwise, it will require warm-up upon restart.
5. If the device remains unused for an extended period after startup (e.g., several hours), it must be initialized before testing.
6. If you suspect that the test data is incorrect, you may retest and extend the test duration.
7. When the instrument is not in use, please turn off the high-voltage power supply to prevent voltage-related damage.
8. Do not place any items on the equipment that are unrelated to the test, to prevent contamination and damage.
9. After the sample test is completed, remove the sample promptly to prevent it from being knocked over and damaging the instrument.
10. When switching between ROHS and XRF, reinitialization is required.
11. Frequent power cycling can also severely damage the instrument.
The above outlines the technical and calibration requirements for using an ROHS testing instrument. If you have any instrumentation needs, please contact us. For more information, ROHS detector information Yes, you may continue browsing our website!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.