Principle and Operating Procedure of Heavy Metal Detectors!

发布时间: 2022-08-30 11:40

Heavy metal detector It features a bilingual Chinese–English interface, with a user-friendly, intelligent design and simple operation. It can be connected to a computer for trial runs. Optimized algorithm integration further enhances measurement accuracy to sub‑ppb levels. Users can leverage the online software to develop additional heavy‑metal detection methods and electrolyte reagents, accommodating a wider range of heavy‑metal analyses and varying water quality conditions across different applications. The instrument’s display directly shows the spectrum, and its integrated algorithms ensure accurate performance even when operated standalone. Below, we’ll explain the principle and operational procedure of the heavy‑metal analyzer.

I. Principle of Heavy Metal Detectors:

After digestion, heavy metals in all forms are converted into ionic species, and a colorimetric reaction occurs upon addition of the appropriate reagents. The measured concentrations are then compared with the permissible limits specified in national standards for agricultural product safety and for pollution‑free vegetable quality, enabling an assessment of the heavy metal content in the vegetable samples.

II. The operating procedure for the heavy metal detector is as follows:

1. Rinse the sample to be tested with distilled or purified water (to remove surface contaminants that might interfere with the analysis), allow it to air-dry, and cut the sample into small pieces approximately 1 cm in size using a knife or scissors. Weigh out 1 g of the prepared sample and place it in a 20 mL plastic sampling tube; then add 10 mL of water.
2. Add 4 drops of Reagent A, use the stirring rod to press the sample below the liquid surface, cap the sampling tube, shake it up and down 10 times, let it stand for 1 minute, then shake it up and down another 10 times. Remove the fruit or vegetable sample; the resulting solution will serve as the sample to be analyzed.
3. Pipette 1 mL of the sample solution into the blank sample tube. Add 3 drops of Reagent B, cap the tube, and shake it up and down five times. Then add 2 drops of Reagent C and 2 drops of Reagent D, shake again five times, and allow the solution to develop color at room temperature for 5 minutes.
4. Compare the sample tube with the rapid test card for lead in fruits and vegetables to obtain a reference concentration of lead in the sample. Note: When the sample contains metal ions such as iron, calcium, or magnesium, the solution color may produce a false‑positive result. This method is suitable for determining free lead. When using a heavy‑metal detector to measure organic lead, digestion must be performed according to standard laboratory procedures.

The above is an introduction to the principles and operating procedures of heavy metal detectors. If you would like to learn more about… Heavy Metal Detector Information Yes, you may continue browsing our website!

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.