News Center

News Center

RoHS 2.0 hazardous substance control standard

发布时间: 2022-08-30 10:30

On June 4, 2015, the Official Journal of the European Union was published. RoHS2.0 The amended Directive (EU) 2015/863 officially adds DEHP, BBP, DBP, and DIBP to the list of restricted substances in Annex II. To date, Annex II includes ten substances subject to mandatory restrictions. So, what are the RoHS 2.0 hazardous substance control standards? Let’s take a brief look below!

I. RoHS 2.0 Hazardous Substances Control Standards – Restricted Substances and Their Limit Values (mass fractions):

Lead (Pb) 0.1%;

Mercury (Hg) 0.1%;

Cadmium (Cd) 0.01%;

Hexavalent chromium (Cr VI) 0.1%;

Polybrominated biphenyls (PBB) 0.1%;

Polybrominated diphenyl ethers (PBDE) 0.1%;

Di(2-ethylhexyl) phthalate (DEHP) 0.1%;

Benzyl butyl phthalate (BBP) 0.1%;

Dibutyl phthalate (DBP) 0.1%;

Diisobutyl phthalate (DIBP) 0.1%.

Following the publication of this revised directive, EU member states are required to transpose it into national law and bring it into effect by December 31, 2016. As of July 22, 2019, all electrical and electronic products exported to Europe—excluding medical and monitoring devices—must comply with the directive’s requirements. Starting July 22, 2021, medical devices (including in vitro diagnostic devices) and monitoring equipment (including industrial monitoring devices) will also fall within the scope of these controls. Furthermore, toy products already subject to the restrictions on phthalates under Article 51 of Annex XVII to REACH remain exempt from the DEHP, BBP, and DBP controls set out in this directive.

Implementation dates for the four new substances: In view of the time required for enterprises to comply with the new requirements on hazardous substances, the relevant transition periods are specified in Regulation (EU) 2015/863: All electrical and electronic products (excluding medical devices and monitoring instruments) shall be subject to the new requirements from 22 July 2019, while medical devices and monitoring instruments shall be subject to the new requirements from 22 July 2021.

II. Amendments to the RoHS Directive:

1. The limit requirements for DEHP, BBP, DBP, and DIBP do not apply to cables placed on the market before July 22, 2019, or to electrical and electronic equipment (EEE) used for repair, reuse, functional upgrading, or as spare parts; nor do they apply to medical devices and monitoring equipment placed on the market before July 22, 2021.

2. The limit requirements for DEHP, BBP, and DBP do not apply to toys that are already subject to the restrictions on DEHP, BBP, and DBP set forth in Article 51 of Annex XVII to EU Regulation No 1907/2006 (REACH).

3. Previously, hexabromocyclododecane (HBCDD) was removed from RoHS 2.0 because the European Commission determined that it falls outside the scope of the RoHS Directive; this substance is already covered by the Stockholm Convention on Persistent Organic Pollutants. According to extensive testing data from accredited laboratories, phthalates, used as plasticizers, are widely employed in electrical and electronic products and may be present in a variety of materials, including wires and cables, plastics, paints, and inks.

Polyvinyl chloride (PVC) is currently one of the most heavily affected materials by phthalate esters, and it warrants close attention from manufacturers. PVC remains a widely used material in the materials industry. However, many companies have yet to see significant progress, as switching to alternative materials would entail increased costs. Although the latest RoHS regulations on phthalates grant manufacturers a three-year transition period, the time required for supply-chain adjustments and process optimizations cannot be overlooked. Consequently, some firms may accelerate their timelines for restricting the use of certain materials in supplier‑provided products. Proactively upgrading manufacturing processes and identifying new environmentally friendly plasticizers as substitutes will be key to meeting the revised RoHS requirements for phthalates.

The above is an introduction to the RoHS 2.0 hazardous substance control standards. If you would like to learn more… RoHS industry information , you can continue browsing our website!

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.

< 12 >