News Center

News Center

What are the five major components of a high-performance liquid chromatograph?

发布时间: 2022-08-24 10:21

High-performance liquid chromatograph They can be classified into four types: liquid–solid adsorption chromatography, liquid–liquid partition chromatography, ion-exchange chromatography, and gel permeation chromatography. The underlying principles and the qualitative and quantitative analytical methods are essentially the same as those used in gas chromatography. So, what are the five major components of a high-performance liquid chromatograph? Below, we will… High-performance liquid chromatography instrument manufacturer - DePu, let me give you a brief introduction!

I. Infusion System

The mobile-phase delivery system of high-performance liquid chromatography comprises a solvent reservoir, a high-pressure pump, and a gradient elution unit. The solvent container is typically made of stainless steel or glass and can hold various mobile phases. The high-pressure pump is one of the key components of an HPLC instrument. Because HPLC columns have small diameters, the stationary-phase particles are fine, and the mobile phase encounters significant resistance, a high-pressure pump is required to propel the mobile phase through the column at higher flow rates. Such a pump must meet the following criteria: generate pressures ranging from 150 to 450 kg/cm²; deliver a stable and adjustable flow rate; and exhibit excellent corrosion resistance. Currently, two types of high-pressure pumps are in use: mechanical pumps and pneumatically amplified pumps. The gradient elution unit enables continuous adjustment of the composition of two or more solvents with differing polarities according to a predefined program, thereby enhancing separation efficiency and reducing analysis time. It functions similarly to the temperature-programming device in gas chromatography.

Gradient elution systems are classified into two types: external gradient systems and internal gradient systems. In external gradient systems, the mobile phases are mixed at atmospheric pressure and then pumped into the chromatographic column under high pressure. In internal gradient systems, the solvents are individually pressurized and then, according to a programmed sequence, pumped into a mixing chamber before being delivered to the chromatographic column.

II. Injector

The injector is the device that introduces the sample into the chromatographic column. There are two injection methods: valve injection and auto‑injection. Auto‑injection is more commonly used for sample loading. In separation systems, high‑performance liquid chromatography typically employs a six‑port valve for sample injection. First, the sample is injected into the sample loop under normal syringe pressure. Then, the valve is switched to the injection position, and the mobile phase delivered by the high‑pressure pump carries the sample into the chromatographic column. Because the volume of the quantitative loop is fixed, injection reproducibility is excellent.

III. Separation System

The high-performance liquid chromatography (HPLC) separation system comprises a chromatographic column, connecting tubing, a temperature controller, and other components. The chromatographic column is the heart of the HPLC instrument. It is typically constructed from internally polished stainless steel tubing, with a length of 10–50 cm and an inner diameter of 2–5 mm, and contains a stationary phase packed inside. In liquid chromatography, the stationary phase is prepared by coating it onto a support material. There are two main types of supports: one is a surface‑porous support, and the other is a fully porous support. In recent years, fully porous particle supports have emerged; these have particle sizes of 5–10 µm and are composed of nanoscale silica particles densely packed together, also known as layered silica beads. Due to their small particle size and high column efficiency, they are widely used. During HPLC analysis, appropriately raising the column temperature can enhance mass transfer, improve separation efficiency, and shorten analysis time. Therefore, a metal jacket equipped with a thermostated heating system can be employed to maintain a constant column temperature throughout the analytical process, with temperature settings ranging from ambient room temperature up to 60°C.

IV. Detector

There are many detectors used in liquid chromatography; the commonly employed ones include the ultraviolet detector, the refractive index detector, and the fluorescence detector.

V. Data Processing and Recording System

Process chromatographic data and participate in the automated control of instruments.

In summary, the five major components of a high-performance liquid chromatograph are the solvent delivery system, the sample injection system, the separation system, the detector, and the data processing system. If you have any needs related to HPLC instruments, please feel free to contact us online or by phone!

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.