The principle of a halogen-free detector!

发布时间: 2022-08-23 10:27

Halogen-free detector It is a system that integrates the halogen directive and eight heavy metal directives. X-ray fluorescence spectrometer It exhibits excellent detection limits and precision for elements such as lead, mercury, cadmium, and barium. X-ray fluorescence spectrometers can determine elemental concentrations by measuring the characteristic X-ray intensities of each element. In recent years, X-ray fluorescence spectroscopy has continued to expand across various industries, becoming a widely adopted analytical technique in metallurgy, geology, non‑ferrous metals, building materials, commodity inspection, environmental protection, and public health—particularly in the field of RoHS testing. So today, let’s discuss the working principle of halogen‑free testing instruments!

Plasma is an ionized gas in which the concentrations of electrons and ions are in equilibrium. This gas contains not only neutral atoms and molecules but also a large number of electrons and ions, making plasma an excellent electrical conductor. Because the densities of positive and negative charges are nearly equal, the system as a whole remains electrically neutral. By employing the principle of high-frequency power induction heating at frequencies ranging from 7 to 50 MHz, a flame‑like plasma is generated by ionizing the working gas—such as Ar, N₂, or air—flowing through a quartz tube, and this plasma is coupled with a high‑frequency plasma torch.

The inductively coupled plasma atomic emission spectrometer (ICP‑AES) applies high‑frequency energy from an RF generator to an inductive coil, positioning the plasma torch at the coil’s center to generate a high‑frequency electromagnetic field. A micro‑spark is used to initiate ignition, ionizing the argon gas flowing through the torch and producing electrons and ions that conduct electricity. Under the influence of the high‑frequency electromagnetic field, the conducting gas forms a toroidal vortex region concentric with the coupling coil; the intense current generates substantial heat, thereby sustaining a torch‑shaped, self‑sustaining plasma. Owing to the skin effect of the high‑frequency current and the action of the carrier gas within the inner tube, the plasma exhibits an annular structure.

The sample is carried by the carrier gas (argon) into the nebulization system, where it is atomized and then enters the plasma’s axial channel in the form of an aerosol. Under high temperature and an inert atmosphere, it undergoes complete evaporation, atomization, ionization, and excitation. The resulting atoms are emitted into the atmospheric environment, and their characteristic spectral lines are dispersed into a spectrum by a grating‑based spectroscopic system. The light at various wavelengths emitted by the constituent atoms is detected by a photomultiplier tube. By determining the presence or absence of specific spectral lines, one can identify whether the sample contains a given element (qualitative analysis); and by measuring the intensity of these lines, one can quantify the concentration of the corresponding element in the sample (quantitative analysis).

The halogen-free detector can also be used to detect various harmful substances in decorative products and to test nickel release from such items. It is capable of analyzing most elemental species and can handle solid, powder, fused‑glass bead, and liquid samples, with an analytical range spanning from beryllium (Be) to uranium (U). It offers rapid analysis, a wide measurement range, and minimal interference.

The above is an introduction to the operating principle of halogen-free detectors. If you have any requirements for such devices, please leave us a message online or contact us by phone. Halogen-free detector manufacturer -De Pu!

Latest News

Recommended Products

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

This page provides information, including frequently asked questions, about the RoHS 2.0 rapid screening instrument PY‑GCMS3080. For pricing inquiries, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Rapid Screening Instrument PY-GCMS3080

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

This page provides an introduction to the DX-320L Pro, a high-performance desktop XRF analyzer compliant with RoHS 1.0. For more information, please contact 19926823034.

Learn more+

RoHS 1.0 Rapid Testing Instrument DX-320L Pro

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

This page provides specifications and FAQs for the DP8300L fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS 1.0 Detector – IDP8300L Fluorescence Spectrometer

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

This page provides specifications and FAQs for the DX-360 fluorescence spectrometer. For pricing inquiries, please contact us online or call 19926823034!

Learn more+

RoHS Six-Item Detector – DX-360 Fluorescence Spectrometer

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

This page provides specifications for the RoHS 2.0 pyrolysis gas chromatograph PY-DP8060, along with FAQs and other information. For a quote, please contact us online or call our hotline at 19926823034!

Learn more+

RoHS 2.0 Pyrolysis Gas Chromatograph PY-DP8060

Halogen detection instrument

This page provides specifications and FAQs for the IDP-6300 halogen detector. For pricing inquiries, please contact us online or call our hotline at 19926823034.

Learn more+

Halogen detection instrument

Frequently Asked Questions

What is RoHS?

RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.

The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.

The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.

What are the limit values for the ten hazardous substances under RoHS?

1. Cadmium: less than 100 ppm.

2. Lead: less than 1000 ppm.

3. Mercury: less than 1000 ppm.

4. Hexavalent chromium: less than 1000 ppm.

5. Polybrominated biphenyls (PBB): less than 1000 ppm.

6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.

7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.

8. Butyl benzyl phthalate (BBP): less than 1000 ppm.

9. Dibutyl phthalate (DBP): less than 1000 ppm.

10. Diisobutyl phthalate (DIBP): less than 1000 ppm.

What instruments are typically used for RoHS testing?

The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.

With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.

Do the ten RoHS items require two instruments for testing?

The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.

Can ROHS testing instruments detect metallic elements?

ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.

Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.