Alloy analyzerCoating Analyzer
Principle of the alloy analyzer system!
发布时间: 2022-08-22 11:24
Alloy analyzer It is an analytical instrument capable of analyzing alloy elements. Many people are interested in understanding the operating principles of alloy analyzers, so let’s provide a brief explanation below.
An alloy analyzer is an XRF spectroscopic technique used to identify and quantify specific elements in a material. It can determine the presence of particular elements by analyzing the wavelength (λ) and energy (E) of the emitted X-rays, and it quantifies the elemental concentration by measuring the intensity of the corresponding X-ray signals. In this way, XRF spectroscopy enables the determination of a material’s elemental composition.
Each atom has a fixed number of electrons—negatively charged particles—orbiting its nucleus. Moreover, the number of electrons equals the number of protons—positively charged particles—in the nucleus. By consulting the atomic number on the periodic table, we can determine the number of protons. Each atomic number corresponds to a specific element; for example, iron has the symbol Fe and an atomic number of 26. Energy-dispersive X-ray fluorescence and wavelength-dispersive X-ray fluorescence spectroscopy techniques are specifically designed to analyze and apply information from the three innermost electron shells—K, L, and M. The K shell is closest to the nucleus, and each electron shell corresponds to a particular energy level for a given element.
In XRF analysis, high-energy primary X-ray photons emitted by the X-ray tube strike the atoms in the sample. These primary photons carry sufficient energy to eject electrons from the innermost (K or L) shell. At this point, the atom becomes an unstable ion. Because electrons naturally seek stability, electrons from the outer L or M shells transition into the space left by the ejected inner-shell electrons. As these electrons move from the outer to the inner shell, they release energy in the form of secondary X-ray photons. This entire process is known as fluorescence. Each element emits characteristic secondary X-rays. The energy of the fluorescent X-ray photons is determined by the energy difference between the inner and outer shells during the electron transition. For example, the Kα emission of an iron atom (Fe) has an energy of approximately 6.4 keV. The number or intensity of X-rays emitted by a specific element over a given period can be used to quantify the amount of that element. A typical XRF energy-dispersive spectrum displays the distribution of photon intensities across different energies.
The above is an overview of the alloy analyzer system’s operating principles, provided for reference only. If you have any needs regarding alloy analyzers, please leave us a message online or contact us by phone. Alloy analyzer manufacturer -De Pu!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.