What factors should be considered when purchasing an ROHS‑compliant fluorescence analyzer?
发布时间: 2022-08-18 11:12
ROHS fluorescence analyzer It is used for determining the content of precious metals such as gold, platinum, and silver, as well as various jewelry items; measuring the thickness of metal coatings; and analyzing the composition of electroplating solutions and coating layers. Below, we will… ROHS detector manufacturer Let’s take a look, together with the editor from Despu Instruments, at what aspects you should consider when purchasing an ROHS‑compliant fluorescence analyzer.
I. Technical Parameters
Generally, you can request samples to be sent to the ROHS‑compliant fluorescence analyzer manufacturer for testing, after which you can proceed with trial runs. During these trials, you can identify any potential issues. Overall, by comparing the results of the trial runs, you can determine which option performs better and is more reliable. Companies typically offer flexible customization based on the manufacturer’s requirements, such as producing non‑standard reference samples, modifying reports, or conducting sample analyses.
II. Technical Training
Recently, the Ministry of Industry and Information Technology has explicitly stipulated that, when selling such products, training must last at least two days. Reputable manufacturers typically conduct training in accordance with this requirement. Failure to provide timely training not only prevents the ROHS fluorescence analyzer from performing optimally but also risks shortening the instrument’s service life due to operator inexperience.
III. After-Sales Service
Unlike other instruments, after-sales service is often critical for products like ROHS fluorescence analyzers. For one thing, fluorescent lamps have a limited lifespan. When components fail, it’s wise to choose models with low maintenance costs. Sellers typically provide technical support after purchase. Many instruments generate substantial revenue through after-sales services. The reason is simple: since each instrument usually requires proprietary detectors and lamp assemblies, replacement parts can only be sourced directly from the manufacturer—often at premium prices. Therefore, many companies offer free repairs but charge heavily for replacement parts; be sure to inquire about pricing in advance before making a purchase.
The above is an overview of what to consider when purchasing an ROHS‑compliant fluorescence analyzer. If you’re in need of such a device, please leave us an online message or give us a call—we’ll get back to you right away!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.