[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Methods for Measuring Carbon and Sulfur Content Using a Metal Element Analyzer!
发布时间: 2022-08-16 09:47
Metal Element Analyzer As a routine… Laboratory instruments It can detect elements in solid, liquid, and gaseous forms, and perform combined measurements and analyses of various elements, including organic solids, highly volatile substances, and sensitive materials. Quantitative analysis of elements such as carbon, hydrogen, nitrogen, and sulfur plays an indispensable role in modern society. So, metals… Elemental analyzer What are the methods for measuring carbon and sulfur content? Let’s briefly go over them below!
To determine the carbon and sulfur contents in steel, the first step is to burn the sample with oxygen in a high‑temperature furnace—such as a resistance furnace, a high‑frequency furnace, or an arc furnace—producing and releasing CO₂ and SO₂ gases. Sulfur is then separated from metallic elements and their compounds, after which the concentrations of CO₂ and SO₂ are measured and converted into the corresponding carbon and sulfur contents in the steel. The following sections describe the gravimetric method for determining carbon and sulfur, as well as the gas‑volume method for carbon determination.
I. Gravimetric Determination of Carbon and Sulfur:
The principle of gravimetric carbon analysis is to burn the sample in oxygen, oxidizing the carbon to CO2. After desulfurization of the resulting gas mixture, CO2 is typically absorbed using alkaline asbestos, and the carbon content is calculated from the increase in weight. For gravimetric sulfur determination, a wet‑chemical method is usually employed: the sample is decomposed with acid to convert the carbon to sulfate, after which BaCl2 is added in an HCl medium to precipitate BaSO4. The precipitate is then collected by filtration, washed, ignited, and weighed to determine the sulfur content. The main drawback of gravimetric analysis is its slow analytical speed, while its advantage lies in its high accuracy. Accordingly, gravimetric methods have been recommended as standard procedures both domestically and internationally.
II. Measurement of Carbon in Gas Volumes:
The classical isobaric gas‑volume method for determining carbon (with measurable values) has been recommended as a standard procedure both domestically and internationally. The sample is placed in a tube furnace, heated and combusted with oxygen, oxidizing the carbon to CO₂. After removing SO₂, the resulting gas mixture is collected in a burette, and its volume is measured. Subsequently, the CO₂ is absorbed using a KOH solution, and the volume of the remaining gas is determined. The difference between the gas volumes before and after absorption corresponds to the volume of CO₂, from which the carbon content is calculated. This method covers a measurement range of 0.05% to 4.0%.
This method is accurate but slow, labor‑intensive, and time‑consuming. To address these limitations, Chinese analysts have proposed a “differential pressure” approach for determining carbon content in gases, developed the theoretical basis for differential‑pressure carbon determination, established the corresponding calculation equation, and designed a dedicated differential‑pressure carbon analyzer. By establishing a specific differential pressure range for carbon measurement, this technique enables rapid carbon‑content analysis within 60 seconds, with high accuracy, thereby significantly enhancing the performance of the gas‑capacity method for carbon determination.
III. Metal Element Analyzers: The methods for determining carbon and sulfur are as follows: non-aqueous titration of sulfur and the potassium iodate volumetric method; conductivity method for carbon and sulfur; coulometric method for carbon and sulfur; infrared method for carbon and sulfur; spectroscopic determination of carbon and sulfur; electrochemical analysis of carbon and sulfur; mass spectrometric analysis of carbon and sulfur; chromatographic analysis of carbon and sulfur; X-ray fluorescence spectroscopy for carbon and sulfur; and activation analysis.
China’s chemical elemental analysis instrument industry has grown from scratch to a substantial scale, yet its overall technological level remains comparable only to that of developed countries in the mid-1980s, and it commands a very small share of the global market. At present, approximately 73% of China’s chemical analysis instruments are imported, with an even higher dependence on imports for certain high-end, precision instruments. Some cutting-edge products are entirely reliant on foreign sources. In short, the backwardness of China’s chemical analysis instrumentation has become a bottleneck hindering the country’s rapid economic development. The above is an introduction to the methods for determining carbon and sulfur content using a metal elemental analyzer. If you have any needs regarding metal elemental analyzers, please feel free to leave us a message online or contact us by phone!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.