[DePu Instruments] – A manufacturer specializing in testing instruments for RoHS compliance, heavy metals, alloy analysis, halogens, and more!
Product Inquiry:19926823034(WeChat ID is the same)
- All
- Product Management
- News and Information
- Introduction Content
- Corporate outlets
- Frequently Asked Questions
- Corporate Video
- Corporate Portfolio
RoHS 2.0 instrument RoHS 1.0 instrument
Alloy analyzerCoating Analyzer
Features, functions, and applications of X-ray fluorescence coating thickness gauges!
发布时间: 2022-08-12 11:14
X-ray fluorescence coating thickness gauge Many people are probably familiar with it, but in fact, quite a few still aren’t fully clear about the X‑ray fluorescence coating thickness gauge’s features, functions, and applications. Below, we’ll provide a brief overview.
I. Features of the X-ray Fluorescence Coating Thickness Gauge:
1. The operation is very simple.
2. Use the laser autofocus function to easily adjust the position.
3. For uneven samples, a reliable anti-collision sensor has also been installed.
4. Equipped with a focus-switching mechanism, it can measure the lower portions of tall samples. (Optional)
5. Equipped with a narrow-gap mechanism, it can measure large-format printing substrates.
II. Functions of the X-ray Fluorescence Coating Thickness Gauge:
Measurable elements: atomic numbers 22 (Ti) to 92 (U); X-ray source: compact air-cooled X-ray tube; tube voltage: 45 kV; tube current: 1 mA; Be window; filters: primary filter—automatic switching; secondary filter—automatic switching; detector: proportional counter; collimators: square—0.2 × 0.05 mm, 0.05 × 0.02 mm; circular—Φ0.1 mm, Φ0.2 mm, Φ0.3 mm; safety features: equipped with sample‑door interlock and collision‑avoidance function; sample‑image focusing: laser‑assisted auto‑focus; sample observation: fixed‑magnification CCD, optional halogen illumination; magnification switching (up to 130×); calibration functions: matrix correction, known‑sample correction, manual input correction; report generation: compatible with MS‑Excel® and MS‑Word® (macro‑enabled automatic report generation); spectral data and sample images can be saved; new thin‑film EP method; reduced complexity in constructing calibration curves and simplified setup of measurement conditions; non‑standardized measurement mode capable of determining film thicknesses of up to five layers; auto‑focus and distance‑correction functions; for samples with uneven droplet distribution, measurement conditions identical to those used in the thin‑film EP method can be applied; enhanced sensitivity; coating‑measurement time reduced by half compared with the company’s previous models; report‑generation capability.
III. Application Areas of X-ray Fluorescence Coating Thickness Gauges
1. Determination of the content of precious metals such as gold, platinum, and silver, as well as various types of jewelry.
2. Measurement of metal coating thickness and determination of plating bath and coating compositions.
3. Primarily used in the precious metals and jewelry industries; banks, jewelry retailers and appraisal institutions; and the electroplating industry.
4. X-ray fluorescence coating thickness gauges can be used for wide-area sample inspection.
5. After capturing a static image of the sample placed on the measurement platform (250 mm × 200 mm), the X-ray fluorescence coating thickness gauge allows you to specify observation locations within narrow regions on the resulting wide-field image. Consequently, the time required to select most measurement points—and to pinpoint specific locations that are difficult to identify in the image—is significantly reduced.
The above provides an overview of the X-ray fluorescence coating thickness gauge’s features, functions, and applications for reference only. If you have any inquiries about this instrument, please feel free to leave an online message or contact us by phone. X-ray fluorescence coating thickness gauge manufacturer -De Pu!
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.