How do you operate a portable RoHS detector correctly?
发布时间: 2022-08-10 11:07
In order to use it correctly Portable RoHS analyzer , to prevent damage to the portable RoHS analyzer caused by improper use and to ensure its service life and measurement accuracy. It is essential to use it correctly. Portable RoHS detector So, how should a portable RoHS detector be operated correctly? It can be broadly categorized into the following methods.
Startup and shutdown sequence for the probe of a portable RoHS analyzer:
1. Power-on sequence: Turn on the regulated power supply, turn on the tester (green light illuminates), turn on the computer host, and then launch the test software.
2. Shutdown sequence: Exit the test software, shut down the computer host, turn off the tester, and then switch off the regulated power supply.
Specifications for the portable RoHS analyzer:
1. Green light – [Power indicator]: When the instrument is powered on, this light illuminates.
2. Yellow light – [Operation Indicator]: This light illuminates during instrument testing and automatically turns off upon completion of the test.
Portable RoHS analyzer operating procedure:
1. The portable RoHS analyzer must be preheated for 30 minutes each time it is powered on. The specific preheating procedure is as follows:
2. Place an appropriate amount of the plastic sample onto the test platform, click [Sample Image] to verify the sample placement, and then click the toolbar.
[RoHS Analyzer Parameter Settings] Set the preheating time to 1800 seconds, click the [CrCLinplastic] measurement curve, and then press the Start button.
[ ] Enter sample information (any input), then click OK to start the preheating measurement (yellow light on). After a test duration of 1,800 seconds, the preheating process is complete.
3. After each power-up or before measuring a sample (following the instrument’s test‑program software being shut down and restarted), an initial calibration must be performed using a pure silver calibration standard. Only after this step has been successfully completed may the next operation proceed. The specific initialization procedure is as follows:
4. On the toolbar, select the “Initialize” option under “Parameter Settings,” insert a pure silver calibration standard as prompted by the system, and click “OK” to begin initialization. After successful initialization, the “Peak Channel” in the status bar should display “1105”; otherwise, reinitialize until this condition is met.
The above is an overview of the operating procedures for the portable RoHS analyzer, provided for reference only. If you have any needs, please feel free to contact us via online consultation or by phone. Our portable RoHS analyzer is widely used for detecting and analyzing environmentally harmful substances—such as those found in raw materials, auxiliary materials, semi-finished products, and finished goods—at the incoming‑material, manufacturing, and shipping stages.
Latest News
Recommended Products
Frequently Asked Questions
What is RoHS?
RoHS is a mandatory standard established by EU legislation, officially known as the “Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.” The standard entered into force on July 1, 2006, and primarily aims to regulate the materials and manufacturing processes of electrical and electronic products, thereby promoting human health and environmental protection.
The purpose of this standard is to eliminate six substances—lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers (note: the correct Chinese term for PBDE is “polybrominated diphenyl ethers”; “polybrominated biphenyl ethers” is an incorrect designation)—and specifically stipulates that the cadmium content must not exceed 0.01%.
The latest RoHS Directive has added four new phthalate‑ester testing items: DEHP—di(2‑ethylhexyl) phthalate; BBP—butyl benzyl phthalate; DBP—dibutyl phthalate; and DIBP—diisobutyl phthalate.
What are the limit values for the ten hazardous substances under RoHS?
1. Cadmium: less than 100 ppm.
2. Lead: less than 1000 ppm.
3. Mercury: less than 1000 ppm.
4. Hexavalent chromium: less than 1000 ppm.
5. Polybrominated biphenyls (PBB): less than 1000 ppm.
6. Polybrominated diphenyl ethers (PBDEs): less than 1000 ppm.
7. Di(2-ethylhexyl) phthalate (DEHP): less than 1000 ppm.
8. Butyl benzyl phthalate (BBP): less than 1000 ppm.
9. Dibutyl phthalate (DBP): less than 1000 ppm.
10. Diisobutyl phthalate (DIBP): less than 1000 ppm.
What instruments are typically used for RoHS testing?
The commonly used analytical instrument for RoHS 1.0 is X-ray fluorescence spectroscopy (XRF). XRF analyzers are available in standalone, benchtop, and handheld configurations. Typically, a handheld XRF analyzer is employed first for portable on-site testing, with a focus on components of the product that pose a higher risk of containing restricted substances.
With the introduction of RoHS 2.0, four phthalate esters have been added to the RoHS Directive, necessitating additional testing to determine the levels of these compounds, which are extracted using solvents. The solvent extracts are then analyzed for the presence of phthalates by gas chromatography–mass spectrometry (GC/MS) or gas chromatography with flame ionization detection (GC/FID). Other elements and polybrominated diphenyl ethers/alkylated elastomers are analyzed using comparative methods and GC/MS, respectively.
Do the ten RoHS items require two instruments for testing?
The ten items specified in RoHS require two instruments for testing.
For the ten‑item RoHS testing, two instruments are required to complete the analysis; a single instrument cannot achieve this. Even if one instrument is used to measure heavy metal content, the other must be employed to analyze organic compounds.
X-ray fluorescence spectrometers are used to detect RoHS 1.0, while chromatographs, pyrolyzers, or hyphenated techniques such as GC–MS are employed to analyze the four phthalates specified in RoHS 2.0. At present, no single instrument can independently perform all the tests required for RoHS 2.0.
Can ROHS testing instruments detect metallic elements?
ROHS testing instruments are specialized devices used to detect the presence of hazardous substances in electronic components, household appliances, toys, and other products. These harmful substances can pose long-term risks to both human health and the environment, making the use of ROHS testing equipment of paramount importance.
Regarding whether ROHS testing instruments can detect metallic elements, the answer is yes. This is because ROHS testing covers not only hazardous substances but also the analysis of metallic constituents in compliant products. These metals include lead, cadmium, mercury, and others, which are widely used during the manufacturing process. Although these elements are essential, their excessive use poses significant risks to human health and the environment. Consequently, the advent of ROHS testing instruments has greatly facilitated the detection of metallic elements.